2 Safety

2.2 General

This operating manual contains general installation, operating and maintenance
instructions that must be observed to ensure safe operation of the system and
prevent personal injury and damage to property.
The safety information in all sections of this manual must be complied with.
The operating manual must be read and understood by the responsible
specialist personnel/operators prior to installation and commissioning.
The contents of this operating manual must be available to the specialist
personnel at the site at all times.
Information attached directly to the product must always be complied with and
kept in a perfectly legible condition at all times. This applies to, for example:
Markings for connections
Name plate
The operator is responsible for ensuring compliance with all local regulations not
taken into account in this operating manual.

2.3 Intended use

• The pump (set) must only be operated within the operating limits described
in the other applicable documents.
• Only operate pump sets which are in perfect technical condition.
• Do not operate partially assembled pump sets.
• Only use the pump to handle the fluids described in the data sheet or
product
• literature of the pump model or variant.
• Never operate the pump without the fluid to be handled.
• Observe the limits for continuous duty specified in the data sheet or
product literature (Qmin and Qmax) (to prevent damage such as shaft
fracture, bearing failure, mechanical seal damage, etc).
• Observe the minimum flow rate and maximum flow rate indicated in the
data sheet or product literature (to prevent overheating, mechanical seal
damage, cavitation damage, bearing damage, etc).
• Do not throttle the flow rate on the suction side of the pump (to prevent
cavitation damage).
• Only operate pumps/pump sets which are in perfect technical condition.
• Consult the manufacturer about any use or mode of operation not
described in the data sheet or product literature.
• Observe the limits for continuous duty specified in the data sheet or
product literature (Qmin and Qmax) (to prevent damage such as shaft
fracture, bearing failure, mechanical seal damage, etc).
• When untreated waste water is handled, the duty points in continuous
operation lie within 0.7 to 1.2 × Qopt to minimise the risk of clogging/
hardening.
• Avoid duty points for continuous operation at very low speeds and small
flow rates (< 0.7 × Qopt).
• Consult the manufacturer about any use or mode of operation not
described in the data sheet or product literature.
Delta Foul V3 Submersible Pump