5 Installation at site

5.2.2 Preparing the place of free-standing (transportable) installations

Incorrect positioning/placing down
Personal injury and damage to property!
 Position the pump set vertically with the motor on top.
 Use appropriate means to secure the pump set against tilting and tipping over.
 Refer to the weights given in the data sheet/on the name plate.
Resonances
Any resonances at the usual excitation frequencies (1 x and 2 x rotational
frequency, blade passing frequency) must be prevented both in the foundation
and in the connected piping, as such frequencies may cause extreme vibrations.
Check the structural requirements
All structural work required must have been prepared in accordance with the
dimensions stated in the outline drawing/general arrangement drawing.

5.3 Installing the pump set

Always observe the general arrangement drawing/outline drawing when
installing the pump set.

5.3.1 Pedestal mounted (stationary) wet installation

5.3.1.1 Fastening the pedestal with chemical anchors
In a concrete sump the pedestal is fastened with chemical anchors.
Figure 4. Fastening the pedestal.
1. Position duckfoot bend 72-1 on the floor of the tank/sump.
2. Insert chemical anchors 90-3.38.
3. Bolt duckfoot bend 72-1 to the floor with chemical anchors 90-3.38.
72-1
90-3.38
Delta Foul V3 Submersible Pump