Servicing/Inspection; Inspection Work - Delta Foul V3 Installation And Operating Manual

Submersible pump
Hide thumbs Also See for Foul V3:
Table of Contents

Advertisement

WARNING
NOTE
Table 10. Overview of maintenance work
Maintenance interval
Every 4,000 operating hours
(at least once a year)
Every five years
36 of 56
Installation and operating manual

7 Servicing/inspection

Insufficient stability
Risk of crushing hands and feet!
 During assembly/dismantling, secure the pump (set)/pump parts to prevent tilting
or tipping over.
A regular maintenance schedule will help avoid expensive repairs and contribute
to trouble-free, reliable operation of the pump, pump set and pump parts with a
minimum of servicing/maintenance expenditure and work.
All maintenance work, service work and installation work can be carried out by Edincare
Pumps or Delta authorised service providers. For contact details please refer to the
enclosed "Addresses" booklet or visit www.edincare.com.
Never use force when dismantling and reassembling the pump set.
7.2 Servicing/inspection
Delta Membranes recommends the following regular maintenance schedule:
Maintenance work
Measure the insulation resistance.
Check the power cable and float switch cable.
Visually inspect the lifting chain/rope.
Change the lubricant.
Inspect the bearings.
General overhaul

7.2.1 Inspection work

7.2.1.1 Checking the lifting chain/rope
The pump set has been lifted out of the pump sump and cleaned.
1. Inspect the lifting chain/rope as well as their fasteners for any visible
damage.
2. Replace any damaged components by original spare parts.
For details refer to...
(
Section 7.2.1.3, Page 37)
(
Section 7.2.1.2, Page 37)
(
Section 7.2.1.1, Page 36)
(
Section 7.2.2.2.4, Page 39)