Delta Foul V3 Installation And Operating Manual

Submersible pump
Hide thumbs Also See for Foul V3:
Table of Contents

Advertisement

Quick Links

Submersible pump
Delta Foul V3
Installation and operating manual
Delta Foul V3
Delta Foul V3
Submersible Pump
Submersible Pump
(Automatic, 230 V, 10 m cable)
(Manual, 230 V, 10 m cable)
DMS 120
DMS E029
www.deltamembranes.com
Technical support 01442 211554

Advertisement

Table of Contents
loading

Summary of Contents for Delta Foul V3

  • Page 1 Submersible pump Delta Foul V3 Installation and operating manual Delta Foul V3 Delta Foul V3 Submersible Pump Submersible Pump (Automatic, 230 V, 10 m cable) (Manual, 230 V, 10 m cable) DMS 120 DMS E029 www.deltamembranes.com Technical support 01442 211554...
  • Page 2 Legal information/Copyright Installation/Operating Manual Delta Foul V3 Submersible Pump. Original operating manual. All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without the manufacturer’s express written consent.
  • Page 3: Table Of Contents

    Glossary ..............................................6 General ..............................................7 Principles ..........................................7 Installation of partly completed machinery ..........................7 Target group ......................................... 7 Other applicable documents .................................. 7 Symbols ...........................................8 Safety ..............................................9 Key to safety symbols/markings................................9 General ..........................................10 Intended use ........................................10 Personnel qualification and training ..............................11 Consequences and risks caused by non-compliance with this manual ...............11 Safety awareness ......................................12 Safety information for the user/operator .............................12...
  • Page 4 Commissioning/Start-up/Shutdown ..............................30 Commissioning/Start-up ..................................30 6.1.1 Prerequisites for commissioning/start-up ......................... 30 6.1.2 Start-up ......................................... 30 Operating limits ........................................31 6.2.1 Frequency of starts..................................32 6.2.2 Operation on the power supply mains ...........................32 6.2.3 Fluid handled .....................................32 Shutdown/storage/preservation ..............................33 6.3.1 Measures to be taken for shutdown ..........................33 Returning to service ....................................34 Servicing/inspection ......................................35 Safety regulations ......................................35...
  • Page 5 Installation and operating manual Submersible pump Delta Foul V3...
  • Page 6: Glossary

    The part of the pump in which the kinetic energy is converted into pressure energy. Pump set Complete pump set consisting of pump, drive, additional components and accessories. 6 of 56 Installation and operating manual Delta Foul V3 Submersible Pump...
  • Page 7: General

    In the event of damage, immediately contact Edincare Pumps on 01442 211 554 or email info@edincare.com to maintain the right to claim under warranty. 1.2 Installation of partly completed machinery To install partly completed machinery supplied by Delta Membranes refer to the sub-sections under Servicing/Maintenance. 1.3 Target group This operating manual is aimed at the target group of trained and qualified specialist technical personnel.
  • Page 8: Symbols

    Conditions which need to be fulfilled before proceeding with the step-by-step instructions  Safety instructions   Results of an action   Cross-references Step-by-step instructions Note Recommendations and important information on how to handle the product 8 of 56 Installation and operating manual Delta Foul V3 Submersible Pump...
  • Page 9: Safety

    Machine damage In conjunction with the signal word CAUTION this symbol indicates a hazard for the machine and its functions. Delta Foul V3 Submersible Pump Installation and operating manual 9 of 56...
  • Page 10: General

    • Avoid duty points for continuous operation at very low speeds and small flow rates (< 0.7 × Qopt). • Consult the manufacturer about any use or mode of operation not described in the data sheet or product literature. 10 of 56 Installation and operating manual Delta Foul V3 Submersible Pump...
  • Page 11: Personnel Qualification And Training

    – Failure of important product functions – Failure of prescribed maintenance and servicing practices – Hazard to the environment due to leakage of hazardous substances Delta Foul V3 Submersible Pump Installation and operating manual 11 of 56...
  • Page 12: Safety Awareness

    • As soon as the work has been completed, re-install and re-activate any safetyrelevant devices and protective devices. Before returning the product to service, observe all instructions on commissioning. ( Section   6.1, Page 30) 12 of 56 Installation and operating manual Delta Foul V3 Submersible Pump...
  • Page 13: Unauthorised Modes Of Operation

    The warranty relating to the operating reliability and safety of the supplied pump (set) is only valid if the equipment is used in accordance with its intended use. Delta Foul V3 Submersible Pump Installation and operating manual 13 of 56...
  • Page 14: Transport/Temporary Storage/Disposal

    1. On transfer of goods, check each packaging unit for damage. 2. In the event of in-transit damage, assess the exact damage, document it and notify Delta Membranes or the supplying dealer and the insurer about the damage in writing immediately.
  • Page 15: Storage/Preservation

    3. Check the power cable for damage. Attach it to the pump handle to prevent it from trailing on the floor. Protect the cable end against moisture. NOTE Observe the manufacturer’s instructions for application/removal of the preservative. Delta Foul V3 Submersible Pump Installation and operating manual 15 of 56...
  • Page 16: Return To Supplier

    Contact your local waste disposal partner for returns. If the used electrical or electronic equipment contains personal data, the user is responsible for deleting it before the equipment is returned. 16 of 56 Installation and operating manual Delta Foul V3 Submersible Pump...
  • Page 17: Description Of The Pump (Set)

    Submersible motor pump for handling domestic waste water, raw water and waste water containing faeces in intermittent operation. Non-explosion proof, non-self-priming. Delta Foul V3 Submersible Pumps are not approved for use in countries stipulating explosion-proof units for handling waste water containing faeces.
  • Page 18: Design Details

    Two design variants are available, depending on the installation type: • Pedestal mounted, eg Delta V3 Foul 800 Series • Free-standing (transportable), eg Delta Foul V3 Packaged Pumping Station The pump set is designed for continuously submerged operation. The motor is cooled by the pumped fluid on the motor surface.
  • Page 19: Configuration And Function

    The pump-end shaft seal is a bi-rotational mechanical seal; the motor-end seal is a shaft seal ring. A lubricant reservoir between the shaft seal ring and the mechanical seal provides cooling and lubrication.. Delta Foul V3 Submersible Pump Installation and operating manual 19 of 56...
  • Page 20: Scope Of Supply

    • Lifting rope/lifting chain (optional) • Mounting bracket with mounting elements • Duckfoot bend with mounting elements • Guiding accessories (guide rails are not included in Delta’s scope of supply) Free-standing (transportable) wet-installations • Pump set complete with power cables •...
  • Page 21: Installation At Site

    Check the structural requirements. All structural work required must have been prepared in accordance with the dimensions stated in the outline drawing/general arrangement drawing. Delta Foul V3 Submersible Pump Installation and operating manual 21 of 56...
  • Page 22: Preparing The Place Of Free-Standing (Transportable) Installations

    1. Position duckfoot bend 72-1 on the floor of the tank/sump. 2. Insert chemical anchors 90-3.38. 3. Bolt duckfoot bend 72-1 to the floor with chemical anchors 90-3.38. 22 of 56 Installation and operating manual Delta Foul V3 Submersible Pump...
  • Page 23  Install a swing check valve in longer riser pipes to prevent the pump from excessive running in reverse. When fitting a swing check valve, make sure that the unit can still be vented properly. Delta Foul V3 Submersible Pump Installation and operating manual 23 of 56...
  • Page 24 5 Installation at site Figure 6. Permissible flange loads Table 6. Permissible flange loads for Delta Foul V3 Pedestal (DN50) Forces [N] Moments [Nm] ΣF ΣM 1350 1650 1500 2600 1000 1150 1400 2050 5.3.1.3 Fitting the guide rail arrangement The pump set is guided into the sump or tank along one vertical guide rails It attaches itself automatically to the pedestal which has been fitted to the floor.
  • Page 25 This attachment point achieves a forward inclination of the pump set towards the discharge nozzle, which allows the pump claw to hook onto the pedestal.. Delta Foul V3 Submersible Pump Installation and operating manual 25 of 56...
  • Page 26: Free-Standing (Transportable) Installations

    Attach the lifting chain or rope to the lug/eyebolt/bail at the pump set on the side of the discharge nozzle. 5.3.2.3 Connecting the piping The DIN connection can be connected to rigid or flexible pipes. 26 of 56 Installation and operating manual Delta Foul V3 Submersible Pump...
  • Page 27: Electrical System

     Never start up a pump set with power cables that have not been fully connected or non-operational monitoring devices. A thermal motor protection device is integrated in the motor. Delta Foul V3 Submersible Pump Installation and operating manual 27 of 56...
  • Page 28: Electrical Connection

     Adjust the length of the power cable to the site requirements. CAUTION Motor overload Damage to the motor!  Protect the motor by a thermal time-lag overload protection device in accordance with IEC 60947 and local regulations. 28 of 56 Installation and operating manual Delta Foul V3 Submersible Pump...
  • Page 29 Figure 12. Fastening the power cables DANGER Touching the pump set during operation Electric shock!  Make sure that the pump set cannot be touched during operation. Delta Foul V3 Submersible Pump Installation and operating manual 29 of 56...
  • Page 30: Commissioning/Start-Up/Shutdown

    Persons in the tank during pump operation Electric shock! Risk of injury! Danger of death from drowning!  Never start up the pump set when there are persons in the tank. 30 of 56 Installation and operating manual Delta Foul V3 Submersible Pump...
  • Page 31: Operating Limits

     Never operate the pump set at ambient or fluid temperatures exceeding those specified in the data sheet or on the name plate.  Never operate the pump set outside the limits specified below.. Delta Foul V3 Submersible Pump Installation and operating manual 31 of 56...
  • Page 32: Frequency Of Starts

     Drain the pump set or protect it against freezing. Refer to the maximum permissible fluid temperature and ambient temperature indicated on the name plate and/or in the data sheet. 32 of 56 Installation and operating manual Delta Foul V3 Submersible Pump...
  • Page 33: Shutdown/Storage/Preservation

     Observe all relevant laws.  When draining the fluid take appropriate measures to protect persons and the environment.  Decontaminate pumps which handle fluids posing a health hazard. Delta Foul V3 Submersible Pump Installation and operating manual 33 of 56...
  • Page 34: Returning To Service

     As soon as the work is completed, re-install and re-activate any safety-relevant devices and protective devices. NOTE On pumps/pump sets older than 5 years we recommend replacing all elastomer seals. 34 of 56 Installation and operating manual Delta Foul V3 Submersible Pump...
  • Page 35: Servicing/Inspection

     Allow the pump set to cool down to ambient temperature. WARNING Improper lifting/moving Personal injury and damage to property!  Always use the pump handle when moving the pump. Delta Foul V3 Submersible Pump Installation and operating manual 35 of 56...
  • Page 36: Servicing/Inspection

    NOTE All maintenance work, service work and installation work can be carried out by Edincare Pumps or Delta authorised service providers. For contact details please refer to the enclosed “Addresses” booklet or visit www.edincare.com. Never use force when dismantling and reassembling the pump set.
  • Page 37 If the insulation resistances measured on the motor are too low, the winding insulation is defective. The pump set must not be returned to service in this case. Delta Foul V3 Submersible Pump Installation and operating manual 37 of 56...
  • Page 38: Lubrication And Lubricant Change

    • Water-glycol mixture WARNING Lubricant contaminating fluid handled Hazard to persons and the environment!  Using machine oil is only permitted if the oil is disposed of properly. 38 of 56 Installation and operating manual Delta Foul V3 Submersible Pump...
  • Page 39 The suction cover and the impeller have been removed. ✔ 1. Place a suitable container under the pump set. 2. Move mechanical seal 433.02 along the shaft. 3. Drain the oil. Delta Foul V3 Submersible Pump Installation and operating manual 39 of 56...
  • Page 40: Drainage/Cleaning

    7.4.1 General information/Safety regulations WARNING Unqualified personnel performing work on the pump (set) Risk of injury!  Always have repair work and maintenance work performed by specially trained, qualified personnel. 40 of 56 Installation and operating manual Delta Foul V3 Submersible Pump...
  • Page 41: Preparing The Pump Set

     Allow the pump set to cool down to ambient temperature. WARNING Components with sharp edges Risk of cutting or shearing injuries!  Always use appropriate caution for installation and dismantling work.  Wear work gloves. Delta Foul V3 Submersible Pump Installation and operating manual 41 of 56...
  • Page 42: Removing The Mechanical Seal And The Motor Section

    Improper reassembly Damage to the pump set!  Reassemble the pump (set) in accordance with the general rules of sound engineering practice.  Use original spare parts only. 42 of 56 Installation and operating manual Delta Foul V3 Submersible Pump...
  • Page 43: Checking The Connection Of Motor/Power Supply

     Wait at least 2 hours before starting the pump again. 7.5.3 Checking the connection of motor/power supply Check the power cables after reassembly. ( Section 7.2.1, Page 37)   Delta Foul V3 Submersible Pump Installation and operating manual 43 of 56...
  • Page 44: Tightening Torques

    Rolling element bearing, pump end 50 % Shaft seal ring, motor end 90 % 433.02 Mechanical seal, pump end 90 % 99-9 Set of sealing elements 100 % 44 of 56 Installation and operating manual Delta Foul V3 Submersible Pump...
  • Page 45: Sets Of Spare Parts

    Rolling element bearing, motor end 321.01 Rolling element bearing, pump end 321.02 Shaft seal ring, motor end Mechanical seal, pump end 433.02 Set of sealing elements 99-9 1 set of circlips Delta Foul V3 Submersible Pump Installation and operating manual 45 of 56...
  • Page 46: Trouble-Shooting

    A Pump is running, but does not deliver B Pump delivers insufficient flow rate C Excessive current/power input D Insufficient discharge head E Vibrations and noise during pump operation 46 of 56 Installation and operating manual Delta Foul V3 Submersible Pump...
  • Page 47 Temperature control device monitoring The motor will restart automatically once it ● the winding has tripped the pump as a has cooled down. result of excessive winding temperatures. Delta Foul V3 Submersible Pump Installation and operating manual 47 of 56...
  • Page 48: Related Documents

    9 Related documents 9 Related documents 9.1 General assembly drawing with lists of components 321.01 81--59 914.01 321.02 412.15 914.02 433.02 412.10 914.03 48 of 56 Installation and operating manual Delta Foul V3 Submersible Pump...
  • Page 49 O-ring Lip seal 433.02 Mechanical seal Ring (Half round head) Grooved pin 81-59 Stator Rotor Cable gland Capacitor Grub screw 914.X Hexagon socket head cap screw Circlip Plate Delta Foul V3 Submersible Pump Installation and operating manual 49 of 56...
  • Page 50: Exploded Views

    9 Related documents 9.2 Exploded view Figure 15. Exploded view of a Delta Foul V3 Submersible Pump (970) (914.01) (100) (834) (412.07) (321.01) (81.59) (818) 81.59 (81.96) (433) (421) 81.96 (321.01/.02) 99-20 (412.07/.10/.15) (932) (410) (932) (914.02/.03) (321.02) (421) (412.15) (330) (914.02)
  • Page 51: Wiring Diagrams

    220/240 V Figure 17. Wiring diagram for a manual pump (controlled by a control panel) White 2. Yellow/green 3. Blue 4. Brown 5. Black 25µF Motor 220/240 V Delta Foul V3 Submersible Pump Installation and operating manual 51 of 56...
  • Page 52: Eu Declaration Of Conformity

    Eastman Way, Hemel Hempstead, HP2 7FW, England herewith declare under sole responsibility, that the products Delta Foul V3 (Automatic) Submersible Pump (DMS 120, serial number F0001 to F9999) Delta Foul V3 (Manual) Submersible Pump (DMS E029, serial number M0001 to M9999)
  • Page 53: Certificate Of Decontamination

    We confirm that the above data and information are correct and complete and that dispatch is effected in accordance with the relevant legal provisions....................................Place, date and signature Address Company stamp Delta Foul V3 Submersible Pump Installation and operating manual 53 of 56...
  • Page 54: Index

    Warranty claims ................7 Maintenance work ..............36 Measure the insulation resistance ......37 Oil quality ..................38 Ordering spare parts .............44 Other applicable documents ..........7 Overload protection .............. 28 54 of 56 Installation and operating manual Delta Foul V3 Submersible Pump...
  • Page 56 151122 Technical support 01442 211554 Delta House, Merlin Way, North Weald, Epping, Essex, CM16 6HR 01992 523 523 | info@deltamembranes.com | www.deltamembranes.com...