Troubleshooting - Gira One 5065 00 Operating Instructions Manual

Dimming actuator 1-gang 200 w with binary input, 3-gang
Table of Contents

Advertisement

Dimming actuator 1-gang 200 W with binary input, 3-gang
Ambient conditions
Ambient temperature
Storage/transport temperature
Dimensions (W × H × D)
Inputs
Control cable (preterminated)
Input type
Number
Total length of extension device cable
Cable type (preferably)
Poll voltage, extension inputs
6

Troubleshooting

Connected LED lamps or compact fluorescent lamps switch off in the lowest dimming
position or flicker
The set minimum brightness is too low.
Increase minimum brightness.
Connected LED lamps or compact fluorescent lamps flicker
Cause 1: Lamps are not dimmable.
Check manufacturer's instructions.
Exchange lamps for another type.
Cause 2: Dimming principle and lamps do not optimally match.
For HV-LED: Check operation in another dimming principle, reduce connected
load as well if necessary.
For LV-LED: Check the lamp operating device and replace as necessary.
With the "Universal" setting: Define the dimming principle manually.
Connected HV-LED lamps or compact fluorescent lamps in the lowest dimming
position are too bright; dimming range is too small
Cause 1: The set minimum brightness is too high.
Reduce minimum brightness.
Cause 2: LED dimming principle (trailing edge phase control) does not optimally
match the connected lamps.
Check operation in the "LED leading edge phase control" setting, reduce con-
nected load as well if necessary.
Exchange lamps for another type.
82404412
02.12.2022
-5 ... +45 °C
-25 ... +70 °C
48 x 50 x 28 mm
YY6x0.6
Potential-free
3
max. 10 m
J-Y(St)Y
approx. 5 V
12 / 19

Advertisement

Table of Contents
loading

Table of Contents