Mini radio blind actuator
The LED blinks. The device is in programming mode for approx. 1 minute.
o
Press radio transmitter
LED lights up red. The radio transmitter has been taught.
i Teach light scene buttons separately.
Exit programming mode
The Venetian blind actuator is in programming mode.
o
Press the programming button briefly.
Venetian blind actuator switches to the operating mode.
i The programming mode is exited automatically after about 1 minute.
Saving the end position of the Venetian blind in a light scene
The upper or lower end position of a Venetian blind can be called up via light scene buttons of a
radio transmitter.
Light scene button of the radio transmitter has been taught in the actuator.
o
Move Venetian blind to the desired end position. The Venetian blind actuator must switch
off by itself.
o
Press desired light scene button of the radio transmitter for at least 3 seconds.
The end position of the Venetian blind has been saved as a light scene.
Deleting radio transmitters individually
o
Teach the radio transmitter to be deleted again (see Teaching a radio transmitter).
LED blinks quickly. The radio transmitter has been deleted.
i If several channels or light scenes of a radio transmitter have been taught, they all must be
deleted individually.
6 Appendix
6.1 Technical data
Rated voltage
Mains frequency
Ambient temperature
Relative humidity
Change-over time for direction change
Switch-on time, Venetian blind operation
Connected load
Motors
Circuit breaker
Switching current for AC 230/240V~ Ohmic
Contact type
Connection
Single stranded
Dimensions Ø×H
Ø Centre hole
carrier frequency
Teachable radio transmitter

6.2 Troubleshooting

Device does not respond, or only sometimes.
Cause 1: battery in the radio transmitter is empty.
Change the battery in the radio transmitter.
Cause 2: Radio range exceeded. Structural obstacles reduce the range.
Check the installation situation.
32534912
449056 I00
29.07.2010
-20 ... +55 °C
approx. 0 % ... 65 % (No moisture
condensation)
approx. 2 min
1.0 ... 2.5 mm²
52.5×27.5 mm
433.42 MHz (ASK)
AC 230 V ~
50 / 60 Hz
approx. 1 s
700 W
max. 10 A
6 A
µ contact
7.5 mm
max. 14
6/7