Troubleshooting; Warranty - Gira System 3000 Operating Instructions Manual

Universal led power booster dra
Hide thumbs Also See for System 3000:

Advertisement

System 3000
Universal LED power booster DRA
5

Troubleshooting

System has switched off.
Cause 1: short-circuit protection has tripped. The power booster behaves like the upstream dim-
mer.
Disconnect system from mains, switch off circuit breakers.
Eliminate short-circuit.
The short-circuit protection is not based on a conventional fuse. Thus the load circuit is
not interrupted electrically.
Cause 2: overheating protection has tripped.
Disconnect system from mains, switch off circuit breakers.
Let system cool down for approx. 15 minutes.
Check the installation situation.
Reduce the connected load.
LED load in leading edge phase control, check if operation is possible in trailing edge
phase control.
LED load, use another type of lamp.
Switch circuit breakers and system on again.
Load is initially distributed to the remaining devices. The further behaviour of the system
depends on the dimmer used and the number, utilisation and installation situation of the
devices.
6

Warranty

The warranty follows about the specialty store in between the legal framework as provided for
by law Please submit or send faulty devices postage paid together with an error description to
your responsible salesperson (specialist trade/installation company/electrical specialist trade).
They will forward the devices to the Gira Service Center. They will forward the devices to the
Gira Service Center.
Gira
Giersiepen GmbH & Co. KG
Elektro-Installations-
Systeme
Industriegebiet Mermbach
Dahlienstraße
42477 Radevormwald
Postfach 12 20
42461 Radevormwald
Deutschland
Tel +49(0)21 95 - 602-0
Fax +49(0)21 95 - 602-191
www.gira.de
info@gira.de
82400102
26.09.2018
6 / 6

Advertisement

loading