Maintenance

dCS audio products do not need regular maintenance. The only user-serviceable part of the unit
is the mains fuse. If the unit is damaged, contact your fulfilment centre.

Replacing a blown mains fuse

There is a fuse below the power inlet of the unit. If the fuse blows, you can replace it.
If the fuse blows once, replace the fuse. There was a power surge.
If the fuse blows repeatedly, contact your dealer to arrange repair. There is a fault in the
unit.
Fuse type: 20 x 5mm T 1A L
WARNING
Replace the fuse with one of the same type and rating. If you use a fuse of a different
type or rating, it may damage the unit and there is a risk of fire or electric shock. It also
invalidates the warranty.
To replace a blown mains fuse:
1. Unplug the power cable from the unit.
2. Next to the power rocker switch, push the two tabs of the fuse holder towards the centre
and pull out the fuse holder.
3. Remove the blown fuse from the lower position of the fuse holder.
4. Replace the blown fuse with the spare fuse from the upper position.