MODEL 208B G1000

ELECTRICAL FAILURES

GENERATOR FAILURE (Amber GENERATOR OFF CAS
MSG)
1. BUS VOLTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CHECK
2. STBY ALT PWR . . . . . . . . . . . . . . . . . . . . . . . . . . . VERIFY ON
IF BUS VOLTS IS LESS THAN 28.5:
3. GEN AMPS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CHECK
IF GEN AMPS IS ZERO:
a. GEN CONT and GEN FIELD Circuit Breakers. . . PUSH IN
b. GENERATOR Switch . . . . . . . . . . . . . . . . . . . . . . . . RESET
IF GENERATOR OUTPUT RESUMES:
c. BUS VOLTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . MONITOR
If BUS VOLTS increases past 32.5, expect the generator to
trip offline again. If this occurs, complete the Generator
Failure checklists beginning with step 3d.
FAA APPROVED
208BPHBUS-01
EMERGENCY PROCEDURES
Monitor voltage and generator output.
(top row last 2 breakers on forward end)
(Continued Next Page)