JUMO LOGOPRINT 500 Operating Manual page 77

Printing recorder with text printing and led dot-matrix display
Table of Contents

Advertisement

Housing
Approvals/
marks of
conformity
Power consumption
Data buffering
Electrical connection
EMC
- Interference emission
- Immunity to interference
Safety standard
Housing type
- housing door
Transport mechanism
Chart paper cassette
Front bezel size
Mounting depth
Control panel cutout
Housing mounting
Ambient temperature range
Ambient temperature error
Storage temperature range
Climatic conditions
Operating position
Protection
Weight
Mark of
Testing
conformity
laboratory
c UL us
Underwriters
Laboratories
7 Electrical connection
Through a lithium battery in RAM > 4 years, or
with a storage capacitor: 2 days at 15 to 25°C ambient temperature.
Additional backup in EEPROM.
At rear through plug-in screw terminals,
conductor cross-section max. 2.5mm
Setup connector at front behind the flip-up
to industrial requirements
Housing for flush-panel mounting to IEC 61 554,
in zinc-plated steel sheet
in corrosion-resistant chrome-nickel steel
in plastic (polycarbonate)
212mm without screw terminals;
227mm with screw terminals plugged in
138
in a control panel to DIN 43 834
-20 to +70°C (without print head), -20 to +55°C (with print head)
20 to 70% rel. humidity, no condensation
NL 90 ± 30, DIN 16 257 (vertical)
to EN 60 529 Category 2,
front IP54 (IP65 with extra code 266),
Certificates /
Test basis
certification numbers
E 201387
UL 3111-1
CAN/CSA
C22.2 No. 1010.1-92
max. 35VA
2
or 2x 1.5mm
dot-matrix display.
EN 61 326
Class B
to EN 61 010
die-cast zinc
144mm x 144mm
+1.0
+1.0
mm x 138
mm
0 to +50°C
0.2%/10°C
rear IP20
max. 3.5kg
valid for
the flush-mounted in-
strument;
not in conjunction with
extra codes 350, 351
and 247
2
with ferrules.
77