Appendix G - Multi-Tech Systems Modem Scripts For; Mac Os - Multitech MT5634MU User Manual

Portable usb modem
Hide thumbs Also See for MT5634MU:
Table of Contents

Advertisement

Appendix G - Multi-Tech Systems Scripts for the Mac OS

Appendix G - Multi-Tech Systems Modem Scripts for

Mac OS

This document discusses the various MultiTech Systems modem scripts available for the Mac OS and where
they should be put in order to use them.
Models Supported By These Scripts
MTA128ST-USB, MTA128ST-USB-RC (Some models are identified with MTA128ST-USB-RC where
the RC indicates there is no support for V.110 via hardware and so the V.110 scripts will not work. The
ATI2 command will indicate the model name).
The above models will be referred to from here on as MTA128ST-USB.
Script Names and Descriptions
MTS MTA128ST-USB V.110 1200
Sets up the MTA128ST-USB in V.110 mode (&F1), disables command echoing (E0), ignores DTR (&D0),
disables auto-answer (S0=0), sets V.110 network rate control to use the $MB/S76 speed (S77=2), and sets
the V.110 network rate to 1200 (S76=2). The default serial baud rate is 1200.
MTS MTA128ST-USB V.110 2400
Sets up the MTA128ST-USB in V.110 mode (&F1), disables command echoing (E0), ignores DTR (&D0),
disables auto-answer (S0=0), sets V.110 network rate control to use the $MB/S76 speed (S77=2), and sets
the V.110 network rate to 2400 (S76=3). The default serial baud rate is 2400.
MTS MTA128ST-USB V.110 4800
Sets up the MTA128ST-USB in V.110 mode (&F1), disables command echoing (E0), ignores DTR (&D0),
disables auto-answer (S0=0), sets V.110 network rate control to use the $MB/S76 speed (S77=2), and sets
the V.110 network rate to 4800 (S76=4). The default serial baud rate is 4800.
MTS MTA128ST-USB V.110 9600
Sets up the MTA128ST-USB in V.110 mode (&F1), disables command echoing (E0), ignores DTR (&D0),
disables auto-answer (S0=0), sets V.110 network rate control to use the $MB/S76 speed (S77=2), and sets
the V.110 network rate to 9600 (S76=5). The default serial baud rate is 9600.
MTS MTA128ST-USB V.110 19200
Sets up the MTA128ST-USB in V.110 mode (&F1), disables command echoing (E0), ignores DTR (&D0),
disables auto-answer (S0=0), sets V.110 network rate control to use the $MB/S76 speed (S77=2), and sets
the V.110 network rate to 19200 (S76=6). The default serial baud rate is 19200.
MTS MTA128ST-USB V.110 38400
Sets up the MTA128ST-USB in V.110 mode (&F1), disables command echoing (E0), ignores DTR (&D0),
disables auto-answer (S0=0), sets V.110 network rate control to use the $MB/S76 speed (S77=2), and sets
the V.110 network rate to 38400 (S76=7). The default serial baud rate is 38400.
MTS MTA128ST-USB V.120
Sets up the MTA128ST-USB in V.120 mode (&F2), disables command echoing (E0), ignores DTR (&D0),and
disables auto-answer (S0=0). The default serial baud rate is 230400.
MTS MTA128ST-USB X.75
Sets up the MTA128ST-USB in X.75 mode (&F3), disables command echoing (E0), ignores DTR (&D0),
and disables auto-answer (S0=0). The default serial baud rate is 230400.
MTS MTA128ST-USB PPP
Sets up the MTA128ST-USB in PPP mode (&F4 &J0), disables command echoing (E0), ignores DTR
(&D0), and disables auto-answer (S0=0). In order to do Multi-Link PPP with this modem script, you must
dial two phone numbers separated by the ampersand symbol (&). For example, 5551000 sets up a single
channel PPP connection and 5551000&5553000 sets up the MTA128ST for a Multi-Link PPP data session.
The default serial baud rate is 230400.
MTS MTA128ST-USB ML-PPP
Sets up the MTA128ST-USB in ML-PPP mode (&F4 &J1), disables Dynamic Bandwidth Allocation
(S59=0), disables command echoing (E0), ignores DTR (&D0), and disables auto-answer (S0=0). The
default serial baud rate is 230400.
MTS MTA128ST-USB ML-PPP w/DBA
Sets up the MTA128ST-USB in ML-PPP mode (&F4 &J1), enables Dynamic Bandwidth Allocation
(S59=1), disables command echoing (E0), ignores DTR (&D0), and disables auto-answer (S0=0). The
default serial baud rate is 230400.
75

Advertisement

Table of Contents
loading

Table of Contents