Rosemount 3051S Wireless Series

Battery Installation

Figure 3-4. Battery Installation
INSTALLING THE
LCD DISPLAY
3-12
Wireless Battery Installation
To make connections, perform the following procedure:
1. Remove the housing cover on the battery compartment side. The battery
supplies all power to the transmitter. Plug and seal both conduit
connections on the transmitter housing to avoid moisture accumulation in
the terminal side.
2. Connect the battery
3. Replace the battery cover and tighten to safety specification (metal to
metal)
Transmitters ordered with the LCD display will be shipped with the display
installed.
NOTE
Only use Rosemount Wireless LCD Part Number: 00753-9004-0002
NOTE
An LCD from a wired device will not function in a wireless device.
In addition to housing rotation, the optional LCD display can be rotated in
90-degree increments by squeezing the two tabs, pulling out, rotating and
snapping back into place.
If LCD pins are inadvertently removed from the interface board, carefully
re-insert the pins before snapping the LCD display back into place.
Use the following procedure and Figure 3-5 to install the LCD display:
1. Remove the battery cover and battery.
2. Remove the transmitter cover opposite the field terminal side. Do not
remove the instrument covers in explosive environments when the circuit
is live.
3. Engage the four-pin connector into the LCD display and snap into place.
Note the following LCD temperature limits:
Operating:–40 to 175 °F (–20 to 80 °C)
Storage:–40 to 185 °F (–40 to 85 °C)