S3 defines the carriage return character by its decimal ASCII code. The default setting is the ^M character
(decimal 13), which is the code for the E
character.
Note: If you change the S3 value, you must make corresponding changes in your data communications
software.
S4
Line Feed Character
Unit: Decimal
Range: 0–127
Default: 10 (^J)
S4 defines the line feed character by its decimal ASCII code. The default setting is ^J (decimal 10), which is
the code for the line feed key on most keyboards that have such a key. S4 may be set for any ASCII
character.
S5
Backspace Character
Unit: Decimal
Range: 0–127
Default: 8 (^H)
S5 defines the backspace character by its decimal ASCII code. The default setting is the ^H character
(decimal 8), which is the code for the BACKSPACE key on most keyboards. S5 may be set for any ASCII
character. Setting S2 to a value greater than 32 disables the backspace character.
Note: If you change the S5 value, you must make corresponding changes in your data communications
software.
S6
Wait Time for Dial Tone
Unit: 1 second
Range: 2–65 (North America), 4–255 (International), 4–7 (U.K.)
Default: 2 (North America), 4 (International and U.K.)
S6 defines the length of time the modem waits after the E
command. The default setting is two seconds for North America, four seconds elsewhere.
S7
Time to Wait for Carrier
Unit: 1 second
Range: 1–255 (USA), 1–45 (Canada and International), or 1–55 (U.K.)
Default: 50 (North America and International) or 55 (U.K.)
S7 determines the amount of time your modem will wait for a carrier signal before it disconnects. The
default value is 50 seconds, except the U.K. model, which defaults to 55 seconds. This means that, after
dialing, the modem waits for a carrier signal for up to 50 or 55 seconds and, if none is detected, terminates
the call. The maximum S7 value is 255 seconds for the USA model, 45 seconds for Canadian and
International models, and 55 seconds for the U.K. model. S7 also determine the wait for silence time for
the @ dial modifier.
S8
Pause Time for Comma
Unit: 1 second
Range: 0–65 (North America), 4–255 (International), 4–7 (U.K.)
Default: 2 (North America), 4 (International and U.K.)
CommPlete Communications Server
key on most keyboards. S3 may be set for any ASCII
NTER
key is pressed before executing a dial
NTER
4 S-Registers