Reading And Assigning S-Register Values; Examples Of Assigning Values - Multitech MT5634HD16 User Manual

Multi-tech mt5634hd16 modems: user guide
Table of Contents

Advertisement

MT5634HD8/16 User Guide
S89
Off-line Time
Unit: 1 second
Range: 0, 5-255
Default: 10
S89 sets the length of time, in seconds, a modem waits in the off-line command mode before it goes into
standby mode. If S89 is set to 20 seconds, the modem waits 20 seconds in off-line command mode before
going into standby mode. Setting S89 to zero (0) prevents the modem from ever entering standby mode.
Setting S89 to any value between zero and five (1-4) effectively sets the value to five, because five seconds
is the minimum possible wait time.

Reading and Assigning S-Register Values

Use the S command to assign a value to an S-register and to read an S-register's current value.
To read an S-register value, in terminal mode, type S, the S-register number, and a question mark (?), and
press E
appear as a three-digit decimal number (e.g., 045 ).
To assign a new value to an S-register, type S, the S-register number, an equals sign (=), and a decimal
number. Convert all ASCII characters to their decimal equivalents before entering them. Valid S-register
decimal values are shown for each register in the previous section. To make the change permanent, use the
&W0 command.

Examples of Assigning Values

1. You want to have longer pauses caused by the comma in a dial command: five seconds instead of
2. You want to configure your modem to answer incoming calls after the fourth ring instead of after the
3. You are calling long distance to another country code, and it is taking a long time to connect. The
38
. For example, to display the value of register S7, type ATS7? and press E
NTER
two. Type ATS8=5 to assign 5 as the value for register S8. The modem will now pause five seconds
for every comma in a dial command.
first ring. To configure register S0 with a value of 4, type ATS0=4 and press E
register S7 (time to wait for carrier) factory default setting of 50 seconds is insufficient; a time-out
occurs and cancels the call before a connection is made. To change the S7 value to 75 seconds, type
ATS7=75 and press E
. Now, after dialing, the modem allows 25 more seconds for a carrier
NTER
signal before aborting the call. The additional 25 seconds should provide enough time for inter-
national calls.
. The answer will
NTER
.
NTER
CommPlete Communications Server

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mt5634hd8

Table of Contents