Using MCSIWSN as an INT14 Redirector
56
-C
Enables the command interpreter. An additional 5 KB of memory is used by
MCSIWSN when the command interpreter is enabled. It allows applications
programs that provide a command interpreter interface to issue the following
commands:
CONNECT, DISCONNECT, HELP, LIST, RESUME, SET, SHOW, SWITCH
-I
Connection Manager connects as inbound. When setting up for inbound-only
connections, adding this parameter string to the command removes the need
for operator intervention to select INBOUND on the Connection Manager
screen.
-P
Adding this parameter to the command line turns on the Connection Manager
OUTBOUND/INBOUND screen.
-A
This parameter enables MCSIWSN to become an INT14-compatible
interface when the COMS14.EXE program is run. See "Using MCSIWSN as
an INT14 Redirector" in the RASExpress User Guide.
-X
This parameter makes MCSIWSN compatible with Novell NASI-based
software
-M
This parameter allows you to wait on a specific line when it is in inbound
mode
-Sx
This option allows a user to wait on multiple servers on the same network
when it is in inbound mode. X is the number of servers available, in the
range 1–9 (default = 1).