Permobil Permolock C Owner's Manual page 31

Locking system for power wheelchair in vehicle
Table of Contents

Advertisement

Owner´s Manual Permolock C
1. Check that the cc distance between
the keyholes is L= 350 mm. and
B= 368 mm. Mark the hole configu-
ration of the plates on the vehicle
floor, see photo.
m
WARNING
The locking plate must always be installed with
its front edge facing the direction of travel, see
photo on page 27.
The plates must be fitted with the narrow end
of the hole in the direction of travel or the
Permolock could come loose in a collision.
2. Drill a Ø6.5mm. hole through the
inner and outer floor of the vehicle,
using the keyhole plate as a tem-
plate.
3. Mark the centre of the keyhole's
large radius. Using a hole-making
tool, drill a Ø60mm hole through
the inner floor of the vehicle, see
photo.
4. Screw the keyhole plates firmly in
place using ISO 10642 M6 10.9
Fe/Zn 5 C1 screws of an appropri-
ate length for the thickness of the
floor.
The screws must go right through
and have a suitable body washer
and nut on the underside.
5. Fix
the
clamp to the locking plate, see
photo.
self-adhesive
Mark the hole configuration
of the plates on the vehicle floor.
The large Ø60 mm hole should be
drilled in the inner floor of the vehicle
tool
31
FORWARDS
368 mm.
only.
Fix the self-adhesive
tool clamp.
Installation