WAGO I/O-SYSTEM 750 510 376 07 Quick Start Manual page 10

Ethernet starterkit 2
Table of Contents

Advertisement

10 •
Quick Start
Ethernet Network Start-Up
Click on the "TCP/IP" tab and enter an IP address for the node. Then, press
the "Write" button to write the change to the node.
Fig. 4: Settings of the 750-841 Controller IP address
Now connect the node to the Ethernet network either directly to a PC using a
crossover cable or to a Hub or Switch using a 1-to-1 patch cable.
Attention
The IP address of the controller can also be assigned using the "WAGO
BootP Server" instead of the "WAGO Ethernet Settings". In this case, the
allocation is done via the Ethernet interface of the device so that no separate
serial cable is required. However, the assigned IP address will only be used
temporarily. In the Web Base Management (WBM), the BootP protocol must
be deactivated subsequently in order to save the IP address permanently.
WAGO-I/O-SYSTEM 750
ETHERNET StarterKit 2