is pressed, and the last button flashing blue light is unable to produce soda water; When the alarm is
low pressure and lack of gas, the button of punching cup should be locked at this time. The following
picture:
Twinkle when
water level is low
CAUTION — If there is an alarm, please check it immediately; otherwise, the drinks will not be qualified. At the
same time, according to the alarm prompt timely replacement of new buckets or cylinders.

Replacement of new bottles (whisky or Flavor)

If the outlet pipe can't make the wine, we need to replace the new bottle; at this time, we should find the
wine that needs to be replaced, open the new bottle, remove the cap; lift the bottle slowly from the
empty bottle, at this time, the residual liquor will flow into the bottle, when there is no residual liquor to
flow out, completely take out the wine tube; then insert into the new bottle; at this time, because there is
residual air in the pipe, we need to empty; The number of the wine pipe (1, 2, 3), put a clean cup on the
drip tray, then press the corresponding empty button until continuous liquor is produced from the outlet
pipe, and the liquor in the glass can be kept and poured into the empty bottle for use.
Twinkle when CO2 pressure is
lower than 63psi