Cornelius Bubble Installation, Operation & Service Manual

Cornelius Bubble Installation, Operation & Service Manual

Post-mix beverage dispenser

Advertisement

Quick Links

Bubble
P
-
B
D
OST
MIX
EVERAGE
ISPENSER
Installation, Operation & Service Manual
Publication Number: 890759403
Revision Date: July 16, 2019
Revision: 2
Visit the Cornelius web site at www.cornelius.com for all your Literature needs.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Bubble and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Cornelius Bubble

  • Page 1 Bubble EVERAGE ISPENSER Installation, Operation & Service Manual Publication Number: 890759403 Revision Date: July 16, 2019 Revision: 2 Visit the Cornelius web site at www.cornelius.com for all your Literature needs.
  • Page 2 This Product is warranted only as provided in Cornelius’ Commercial Warranty applicable to this Product and is sub- ject to all of the restrictions and limitations contained in the Commercial Warranty.
  • Page 3: Table Of Contents

    Key and flavor Description ......................17 Adjusting the ratio of drinks ......................17 Alarm function ..........................20 Replacement of new bottles (whisky or Flavor) ................21 Method of changing Wine Cups of Different Sizes ................22 Cleaning..........................25 ©2019, Cornelius Inc.
  • Page 4 Pump Motor Replacement ......................30 Agitator Motor Replacement ......................30 Controller Board Replacement ....................... 30 Condenser Fan Motor Replacement ....................30 ........................31 ROUBLE HOOTING ......................... 35 EFERENCE ATERIAL Wiring Diagram ..........................35 Plumbing Diagram .......................... 36 ©2019, Cornelius Inc.
  • Page 5: Safety Instructions

    Cleaning and user maintenance shall not be made by children without supervision. • Keep your unit in proper working condition and do not allow unauthorized modifications to the unit. UALIFIED ERVICE ERSONNEL © 2019, Cornelius Inc...
  • Page 6: Safety Precautions

    Plug should also be earthing type and obtain approval with above cord. OUND EVEL The A-weighted sound pressure level has been determined to be below 70dBA. OCATION This unit is not designed for use in outdoor locations. © 2019, Cornelius Inc...
  • Page 7: General Instructions

    Install Date: Lacal Authorized Serviced Center: ESCRIPTION The Bubble post-mix, high-ball dispenser is all in one,plug and play unit.Also it have several advanced functions such as water and CO2 alarm etc.. Bubble The Bubble-Beverage dispenser is an all in one whiskey drinks machine, plug-and-play, and can provide a variety of different types of alcoholic drinks with different tastes.
  • Page 8: Unit Specification

    PECIFICATION Table1 Height 34 inches 862mm Width 16 inches 409mm Depth 27 inches 685mm Shipping weight(approx) 165Pounds 75Kg Water Bath Size 13 gal (US) Ice Bank Weight 23Ib © 2019, Cornelius Inc...
  • Page 9: Theory Of Operation

    © 2019, Cornelius Inc...
  • Page 10 Notes © 2019, Cornelius Inc...
  • Page 11: Installation

    If any damages exist, file a claim with the shipment carrier. Table2 Accessories Part No. Quantity Cup rest Power cord Drain Hose 50119 Clamps 70339 Decals Varies with dispenser 1 set Manual 890759403 © 2019, Cornelius Inc...
  • Page 12: Installation Requirements

    CAUTION — Avoid spillage into the top vents. NSTALLATION ROCEDURE Counter-top Installation WARNING: The unit is heavy and extreme care should be taken when moving or lifting the unit. Do not attempt to lift the unit © 2019, Cornelius Inc...
  • Page 13 2 cm higher than the suction pipe; then insert the bottled water; at the same time, connect the water level control signal wire and fasten the nut; Water inlet -Water suction pipe -Water level probe -positioning plate Fasten the nut of signal wire © 2019, Cornelius Inc...
  • Page 14 Connect the carbon dioxide pipe Take out the drip tray Realese the soda water valve & internal parts © 2019, Cornelius Inc...
  • Page 15 CAUTION — The equipment should be installed in the use area and be convenient for the maintenance of trained professional maintenance personnel. 4. Installation of alcoholic drinks: The equipment can only be built-in 3 alcoholic drinks, © 2019, Cornelius Inc...
  • Page 16 5. Connect the power cord, turn on the main power supply, turn on the LED light switch above the light box, and the light box will turn on. Close the light box and lock the lock and buckle. Power cord © 2019, Cornelius Inc...
  • Page 17 (the first button) to exhaust. At this time, the water level in the bucket will drop, and when the water level of the carbonized tank reaches, the pump will stop. Soda water © 2019, Cornelius Inc...
  • Page 18: Global Ice Bank Control (Gibo) Theory Of Operation

    © 2019, Cornelius Inc...
  • Page 19: Key And Flavor Description

    Among them, 1 must be used for whiskey. Five buttons in front of the light box are fixed to the soda water button for the first button (left number on the front of the machine). The following figure is specific: © 2019, Cornelius Inc...
  • Page 20: Adjusting The Ratio Of Drinks

    Adjusting the ratio of drinks 1. The flow rate of liquor and water can be adjusted. 2. Open the light box with a blue film-covered keyboard and a small screen on the back. The following picture: © 2019, Cornelius Inc...
  • Page 21 < mobile > button, you can switch to it. It has three counting tastes; the director saves and exits by pressing the < procedure > key. Then the number of cups corresponding to the selected taste will be zero. Reset number © 2019, Cornelius Inc...
  • Page 22 < counting > key, which is the reference value of 000-999. The higher the value, the higher the speed, and press the < program > key to save and exit for a long time. © 2019, Cornelius Inc...
  • Page 23: Alarm Function

    © 2019, Cornelius Inc...
  • Page 24: Replacement Of New Bottles (Whisky Or Flavor)

    The number of the wine pipe (1, 2, 3), put a clean cup on the drip tray, then press the corresponding empty button until continuous liquor is produced from the outlet pipe, and the liquor in the glass can be kept and poured into the empty bottle for use. © 2019, Cornelius Inc...
  • Page 25: Method Of Changing Wine Cups Of Different Sizes

    When using the small cup, the platform is moved to the center of the cup and placed on the small cup to make a cup. As shown in the picture: Big cup © 2019, Cornelius Inc...
  • Page 26 Small cup Note: For Korean model, there is no small cup rest. © 2019, Cornelius Inc...
  • Page 27 Notes © 2019, Cornelius Inc...
  • Page 28: Cleaning

    -The disinfectant should be kept in the pipeline for at least 10 minutes, but not more than 15 minutes. In order to avoid sterilizing the water-freezing tube, it is required to press the empty key several times during the process. © 2019, Cornelius Inc...
  • Page 29: Condenser Cleaning

    1. Disconnect electrical power to the dispenser. 2. Remove the air filter through the cut out on top panel. 3. Vacuum and use soft brush to clean the filter. 4. Place the cleaned filter back in position. © 2019, Cornelius Inc...
  • Page 30 Notes © 2019, Cornelius Inc...
  • Page 31: Service

    4. Vacuum or use a soft brush to clean condenser coil. If available, use low pressure compressed air. 5. Clean around top of refrigeration assembly. 6. Reinstall side panels and top panel and close the merchandiser. © 2019, Cornelius Inc...
  • Page 32: Adjustments

    When lines are fully pressurized open the valve all the way until it back-seats itself (this prevents leaks from the valve). 2. The Bubble dispenser with integral cold carbonator requires CO supply pressure of 85 psi ;...
  • Page 33: Component Service

    2. Remove top panel, side panels and back panel. 3. Unplug motor harness. 4. Remove fan mounting Screw 5. Lift up fan Motor Assembly. 6. Remove fan motor. 7. Install new motor by reversing this procedure. © 2019, Cornelius Inc...
  • Page 34: Trouble Shooting

    - The pump does not work - Check whether the DC power supply in the electronic control box works. 3. Water in the tank is frozen. - Water pipes covered with ice, frozen pipes 4. No action of outlet solenoid valve © 2019, Cornelius Inc...
  • Page 35 Compressor operates continuously 2. Unit located in excessively hot area or 2. Relocate unit or check and if but does not form sufficient ice bank. air circulation through condenser coil is necessary, clean condenser coil as restricted. instructed. © 2019, Cornelius Inc...
  • Page 36 Fan Motor Not Operating” in this section. 10. Inoperative overload protector or start 10. Replace inoperative part. relay. 11. Replace ice bank probe. 11. Inoperative ice bank probe. 12. Replace control board. 12. Inoperative control board. © 2019, Cornelius Inc...
  • Page 37 Notes © 2019, Cornelius Inc...
  • Page 38: Reference Material

    REFERENCE MATERIAL IRING IAGRAM © 2019, Cornelius Inc...
  • Page 39: Plumbing Diagram

    LUMBING IAGRAM © 2019, Cornelius Inc...
  • Page 40 Cornelius Inc. www.cornelius.com...

Table of Contents