Cornelius Bubble Installation, Operation & Service Manual page 36

Post-mix beverage dispenser
Table of Contents

Advertisement

`
Carbonator pump not operating
Agitator motor not operating.
Refrigeration compressor does not
operate.
1. 3 minutes run limit exceeded.
2. Water supply to carbonator disrupted.
3. Carbonated water tank water level
probe electrical wiring disconnected.
4. Inoperative carbonated water tank
water level probe.
5. Inoperative carbonator pump or motor.
6. Inoperative control board.
1. No power source (blown fuse or tripped
circuit breaker).
2. Agitator motor propeller obstructed.
3. Low Voltage.
4. Loose, disconnected, or broken wiring.
5. Inoperative agitator motor.
1. Ice bank sufficient.
2. No water in water tank.
3. Control board power switch on top of
unit in "OFF" position.
4. Unit power cord un- plugged, or drop-in
refrigeration assembly power cord
unplugged.
5. Ice sensor electrically disconnected.
6. No power source (blown fuse or tripped
circuit breaker).
7. Low/high voltage.
8. Loose, disconnected, or broken wiring.
9. Overload protector cut out; overheated
compressor. Condenser fan motor not
operating as required.
10. Inoperative overload protector or start
relay.
11. Inoperative ice bank probe.
12. Inoperative control board.
32
1. Turn power OFF for 15 second.
2. Correct water supply problem.
3. Connect electrical wiring to water
level probe (see note).
4. Replace probe (see note).
5. Replace pump or motor.
6. Replace control board.
1. Replace fuse or reset circuit breaker.
(NOTE: Fuse or circuit breaker are
not part of unit).
2. Remove obstruction.
3. Voltage must be 90- 135VAC (110-
120 volt unit) or 180-260(230 VAC
unit) at compressor terminals when
compressor is trying to start.
4. Tighten connections or replace
broken wiring.
5. Replace agitator motor.
1. No refrigeration called for.
2. Fill water tank with water as
instructed.
3. Place control board power switch in
"ON" position (will be a built-in 3-minute
time delay before refrigeration
compressor starts).
4. Plug in power cord.
5. Electrically connect or replace
inoperable sensor.
6. Replace fuse or reset circuit breaker.
(Note: Fuse or circuit breaker are not
part of unit).
7. Voltage must be 180- 255 Volts or 90
-130Volts.
8. Tighten connections or replace
broken wiring.
9. Compressor will cool enough to
restart, Do not overdraw cooling
capacity of unit. Refer to "Condenser
Fan Motor Not Operating" in this
section.
10. Replace inoperative part.
11. Replace ice bank probe.
12. Replace control board.
© 2019, Cornelius Inc