BEVERAGE NOT SWEET ENOUGH.

BEVERAGES NOT COLD (UNITS WITH BUILT-IN
COLD PLATE).
FLAVOR SYRUPS DO NOT DISPENSE.

FLAVOR DISPENSES FOR MORE THAN 1 SEC.

FLAVOR DISPENSES MORE THAN .5 OZ.

Contact your local syrup or beverage equipment distributor for additional information and troubleshoot-
ing of beverage system.
92181INS
Probable Cause
A. Empty syrup tank.
B. Faucet brix requires adjusting.
A. Unit standing with no ice in hopper or no ice in cold
plate cabinet.
A. No 24 volt power to PC board.
B. No CO2 pressure.
C.Empty syrup tank.
D.Kinked tubing.
E. Clogged inner nozzle.
F. Defective PC board.
G.Defective harness from keypad.
H.Defective Flow control.
I. Defective solenoid harness.
J. Defective keypad.
A. Dip switch settings on control board incorrect.
B. PC board defective.
C.Defective flow control.
A. Dip switch settings on control board incorrect.
B. Flow control incorrectly set.
C.PC board defective.
D.Defective flow control.