The ice bank control operates the compressor and condenser fan motor to control the size of the ice bank. The control
board will not restart the compressor until after the compressor has been off for at least 3 minutes to
allow the refrigeration system pressures to equalize.
Carbonator Control
The carbonator control operates the integral carbonator pump to maintain the water level in the carbonator tank within
pre-established limits. A programmed timer shuts down the carbonator pump motor if it operates
continuously for more than 3 minutes. This prevents the carbonator from running continuously if there is a water leak or
loss of water supply.
Voltage Cutout Protection
The control board monitors the input line for high and low voltage conditions. If the voltage is outside of the acceptable
range, the control will not allow certain operations (to protect motors from damage).

Key and flavor Description

1. There are three kinds of alcoholic drinks in the equipment. There are two optional working modes:
one requires two bottles of whiskey and one bottle of liqueur. Mode 2 requires 1 bottle of whiskey and 2
bottles of liqueur.
2. There are three sets of suction pipe components inside the equipment, labeled with 1, 2, and 3.
Among them, 1 must be used for whiskey. Five buttons in front of the light box are fixed to the soda
water button for the first button (left number on the front of the machine). The following figure is specific:
15
© 2019, Cornelius Inc

Advertisement

Table of Contents
loading

Table of Contents