Sinclair S therm Series Service Manual page 82

Split heat pumps
Table of Contents

Advertisement

Select "Period 1"/"Period 2" and a window will pop up, where time period can be set. Then select "WT-Heat1/
WT-Cool 1/2" and also a window will pop up where temperature can be set.
[Notes]
●When "Weekly timer", "Preset mode","Clock timer" "Temp. timer" have been set at the same time, then the
latter takes the priority.
●This setting is valid only when the unit is turned on.
●Under the "Cool" or "Cool+Hot water" mode, the setting targets at "WT-Cool"; while under the "Heat" or
"Heat+Hot water" mode, the setting targets at "WT-Heat".
●When start time of period 2 is the same as that of period 1, then the former takes prevalence.
●"Temp.timer" is judged based on timer.
●During this setting, when temperature is set manually, then this setting will take prevalence.
●Under the "Hot water" mode, this function will be reserved.
●This function will be memorized upon power failure.
3.2.2.12 Emergen. Mode
[Operation Instructions]
1.At the function setting page, set the mode to "Heat" or "Hot water".
2.At the function setting page, select "Emergen.mode" and set it to "On" or "Off".
3.When "Emergen.mode" has activated, the corresponding icon will appear at the upper side of the menu page.
4.When the mode is not set to "Heat" or "Hot water", the display panel will tell "Wrong running mode!"
[Notes]
●The emergency mode is allowed on conditions that there is some error or protection and the compressor has
stopped at least for three minutes. If the error or protection has not been recovered, the unit can access to the
emergency mode through the wired controller (when the unit is off).
●Under the emergency mode, "Hot water" or "Heat" cannot be performed at the same time.
●When the running mode is set to "Heat", if "Other thermal" or "Optional E-Heater" is set to "Without", the unit
will fail to access to the "Emergen. mode".
●When the unit performs "Heat" under "Emergen. mode" and the controller detects "HP-Water Switch",
"Auxi. heater 1", "Auxi. heater 1", and "Temp-AHLW", this mode will quit at once. In the same way, when errors
mentioned above occur, "Emergen. mode" cannot be activated.
●When the unit performs "Hot water" under "Emergen. mode" and the controller detects "Auxi.-WTH", this
mode will quit at once. In the same way, when errors mentioned above occur, "Emergen. mode" cannot be
activated.
●When this function has been activated, "Weekly timer", "Preset mode", "Clock timer",and "Temp timer" will
be deactivated. Beside "On/Off", "Mode", "Quiet mode", "Weekly timer", "Preset mode", "Clock timer",and "Temp
timer" operation are unavailable.
●Under "Emergen. mode", the thermostat does not work.
●This function can be activated only when the unit is turned off. If dosing so with the unit keeping "On", a
window will pop up, saying "Please turn off the system first!".
78

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents