Sinclair S therm Series Service Manual page 73

Split heat pumps
Table of Contents

Advertisement

Icon
Description
Water heating
Menu
Switchover
between cooling
and heating
[Notes]
●The ON/OFF icon will turn to green when the control is turned on.
●When the control mode is "Room temperature", the temperature displayed at the upper right corner indicates
the remote room temperature; when the control mode is "leaving water temperature", it indicates the leaving
water temperature of the auxiliary electric heater under the water heating mode, or the leaving water temperature
of the main unit under the cooling/heating mode or combined modes.
●Under the combined modes, the temperature set point is for space heating or cooling. Only under the water
heating mode, it is for water heating.
●It will go back automatically to the homepage when there is no operation in ten minutes.
3.1.2 Menu Page
Above the menu, the corresponding icon will be displayed based on the mode and status of the controller.
No
Item
1
Current mode
2
Data
3
Time
4
Function setting
5
Parameter setting
6
Parameter viewing
7
Commissioning parameters
8
ON/OFF
9
General setting
10
Homepage
Icon
10
Current mode
Current data
Current time
Go to the user setting page.
Go to the parameter setting page.
Go to the parameter viewing page.
Go to the commissioning parameter setting page.
It is used to turn on or off the unit. "OFF" indicates the unit has turned off and "ON"
indicates the unit has turned on. When there is failure-level error, this button will
turn to OFF once the unit is automatically turned off.
Go to the general parameter setting page.
Back to the home page.
Error
Card out/Failed disinfection
ON/OFF
Menu Page
Description
69
Description