1. MAC address of the GDS37xx (check the sticker at back of the device)
2. Default password of the GDS37xx (check the sticker at the back of the device)
3. Correct decoding the last 6 MAC address into digits (refer to encoding rule)
4. Correct decoding the default password into digits (refer to encoding rule)
5. Finish keypad input within 1 minute
Operation Steps:
1) When device is idle, input the special keypad combination with format: ***last_6_MAC**#
2) Device will reach restore mode after correct digits in Step 1) entered. The backlight of keypad will flash quickly to tell operator the device is
now in password reset/restore mode.
3) Operator will enter the correct decoded default password ending with # with format: default_password_code# via the keypad within 60
seconds.
4) If wrong code combination entered, the GDS37xx will beep with error sound (three short beeps) then exit the password reset mode, and the
backlight will stop flashing.
5) If the correct default password decoded entered within 60 seconds, GDS37xx will play a long beep sound (advising correct operation), the
device will reboot itself automatically.
6) If keypad entry time out (not finish the input within 60 seconds), the device will exit this password reset mode automatically and stop the
backlight flashing. After successful password reset, operator will then be able to log into the GDS37xx webUI with default password, all the
configuration inside the device will be the same and will NOT be changed.
For example:
Decoding the string into digits and write to paper before doing the operation:
Device with last 6 MAC address: 33DDDD
Decoding the last 6 MAC to digits would be: 334444
Default password is: xwpxz6AA
Decoding the default password to digits would be: 2423162426611
1) Enter ***334444**# via keypad, get into the password reset mode, the keypad backlight will flash quickly. 2) Within 60 seconds, enter
2423162426611#, the device will play one long beep then reboot itself.
2) Wait the device finishing boot up, log in the webUI using the default password, xwpxz6AA

CHANGE LOG

This section documents significant changes from previous versions of user manual for GDS3710. Only major new features or major document
updates are listed here. Minor updates for corrections or editing are not documented here.
Firmware Version 1.0.11.23
Product name : GDS3712, GDS3710
Added ability to disable alarm siren sound in triggered alarm call.
Added "Keep Door Open" to be configured to use multiple schedules and allow users to choose and apply which schedule to use.
Open
Door]
Added granular DIGITAL OUTPUT time duration (1s to 4s).
Added sending PIN via Wiegand when HTTP API open door executed.
Added option that no "#" is required after PIN input to make the device behave like a traditional access controller when "Disable Keypad SIP
Number Dialing" is selected.
[Local PIN
Added firmware upgrade via manually uploading firmware files from the
Optimized speaker via OQA testing.
Updated CPE version to 1.0.5.5
Firmware Version 1.0.11.18
Table 116: Encoding rule
[Doorbell
Type]
[Audio
Testing]
[CPE
Version]
[Enable/Disable Silent Alarm
Mode]
Mode]
[Door Relay
Options]
computer.[Upgrade via Manually
[Schedule
Upload]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gds3712Gds3710

Table of Contents