Step 3.
Install the backplane onto the middle drive cage.
Figure 203. Installing the middle 2.5-inch drive
backplane
a.
Align the bottom of the backplane with the studs at the bottom of the drive cage, and lower the
backplane into the drive cage.
b.
Push the top of the backplane forward until it clicks in place. Ensure that the holes in the
backplane pass through the pins on the drive cage, and the release latches secure the
backplane in position.
After you finish
Install the drive cage onto the chassis. See "Install the middle drive cage" on page 276.

Install the middle drive cage

Use this information to install the middle drive cage.
About this task
Attention:
• Read "Installation Guidelines" on page 185 to ensure that you work safely.
• Power off the server and disconnect all power cords for this task.
• Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-
sensitive components in their static-protective packages until installation, and handling these devices with
an electrostatic-discharge wrist strap or other grounding system.
• The middle drive cage is supported on some server models with thermal requirements. See "Thermal
rules" on page 192 to ensure that the server is under permitted ambient temperature and the correct heat
sink and system fans are used. If needed, replace your heat sink or system fan first.
– "Processor and heat sink replacement (trained technician only)" on page 297
– "System fan replacement" on page 364
• If you are upgrading the server to the 32 x 2.5-inch NVMe configuration, replace your cable wall bracket
first. See "Cable wall brackets replacement" on page 201.
ThinkSystem SR650 V2Maintenance Manual
276
Figure 204. Installing the middle 3.5-inch drive
backplane