Step 1.
Install the Torx T30 nut.
Figure 171. Installing a Torx T30 nut into the heat sink
Note: Do not touch the gold contacts on the bottom of the processor.
a.
Rotate the anti-tilt wire bail inwards.
b.
Orient the Torx T30 nut under the anti-tilt wire bail; then, align the Torx T30 nut with the socket
at an angle as shown.
c.
Push the lower edge of the Torx T30 nut into the socket until it clicks into place. Make sure the
Torx T30 nut is secured under the four clips in the socket.
After you finish
1. Reinstall the PHM. See "Install a processor and heat sink" on page 301.
2. Complete the parts replacement. See "Complete the parts replacement" on page 381.
ThinkSystem SR650 V2Maintenance Manual