c) Release the wire bundle from the harness clip.
12. Locate the storage area of the press that holds the pack of Fuser and Pressure Roll
Lift Handles. Remove the Lift Handles pack from the storage area.
13. Place the Fuser Belt Module Handles on the posts on each end of the module.
14. Facing the right side of the drawer, push the module slightly away from you and lift
the Fuser Belt straight up and out of the press, letting the weight of the module hang
in your hands.
Note
Do not twist or rotate the module as you place it in the Holding Rack.
15. Place it on the Fuser Holding Rack provided. Align the edge of the roller to the scribe
mark on the holding rack frame.
16. If damaged or end-of-life, place it inside the original box and return to Xerox for
recycling.
17. With the Fuser Belt removed, you can now remove and replace the Fuser Stripper
Finger Bracket, the Fuser Pressure Roll Assembly and the Pressure Roll Cleaning Pad
Assembly. Refer to those procedures.
18. If a different width fuser is going to be installed, remove the new fuser from its
packaging. Store the unused fuser in its original box.
19. To install the fuser, refer to that procedure

Replacing the Stripper Finger Assembly

Caution
Make sure the press is powered off. Do not perform this replacement procedure with
the power on or electrical power supplied to the press. Allow the fuser to cool down for
50 minutes before performing any maintenance.
®
®