CONNECTION OF THE ELECTRIC WIRES
Connection of junction
3
Wind any excess length of electric wire inside junction [B] to adjust the length.
Example of adjusting junction [B] length
4
5
To be continued on next page
Temporarily secure the electric wire
along the frame with tape, and connect
it to junction [B].
Once the electric wires have been
(A)
routed, secure junction [B] underneath
the bottom bracket shell.
53
NOTICE
When routing the electric wire to the
motor unit, be sure to install it to the
bottom of the chainstay to avoid any
interference between the cable and the
chain.
If the motor unit is the MU-UR510, use the
EW-AD305 to connect the EW-SD50 and
EW-SD300, then connect them to junction
[B].
(A)
Junction [B] fixing bolt
(10.5 mm or 15 mm)
Tightening torque
1.5 - 2 N·m