Diagnostics
■
LEDs
The adapter module has one diagnostic LED.
Color
Description
Green
The adapter module is powered up.
Red
There is no communication with the drive control unit or the adapter
module has detected an error.
Technical data
Installation
Degree of protection
Ambient conditions
Package
Analog inputs (80..82, 83..85, 86..88)
Maximum wire size
Input voltage ( AI+ and AI-)
Input current ( AI+ and AI-)
Input resistance
Optional cable shield connections
Analog outputs (90..92, 93..95)
Maximum wire size
Output voltage (AO+ and AO-)
Output current (AO+ and AO-)
Output resistance
Recommended load
Inaccuracy
Optional cable shield connections
CAIO-01 bipolar analog I/O adapter module 259
Into slot 2 of drive control unit
IP20 / UL 1 Type
See the drive technical data.
Cardboard
1.5 mm 2
-11 V ... +11 V
-22 mA ... +22 mA
>200 kohm (voltage mode), 100 ohm (current
mode)
1.5 mm 2
0 V ... +11 V
0 mA ... +22 mA
< 20 ohm
>10 kohm
± 1% Typical, ± 1.5% Max of full-scale value