154 Maintenance
Recommended annual actions by the user
Action
Description
P
Capacitor reforming for spare modules and spare capacitors
I
Tightness of terminals
I
Dustiness, corrosion or temperature
P
Heatsink cleaning
Recommended maintenance actions by the user
Component
Cooling
Main cooling fan
Main cooling fans
Auxiliary cooling fan
Auxiliary cooling fan
Second auxiliary cooling fan (IP55, UL Type 12)
Aging
Control panel battery (real-time clock)
Functional safety
Safety function test
Safety component expiry (Mission time, T M )
Note:
Maintenance and component replacement intervals are based on the
assumption that the equipment is operated within the specified ratings and
ambient conditions. ABB recommends annual drive inspections to ensure the
highest reliability and optimum performance.
Long term operation near the specified maximum ratings or ambient conditions
may require shorter maintenance intervals for certain components. Consult
your local ABB Service representative for additional maintenance
recommendations.
Years from start-up
3
6
9
12
15
18
R
R
R
R
R
R
R
R
I
See the maintenance in-
formation of the safety
function
20 years
4FPS10000309652
21