196 Technical data
ACH580-
Frame
31-...
size
12A7-4
R3
018A-4
R3
026A-4
R3
033A-4
R6
039A-4
R6
046A-4
R6
062A-4
R6
073A-4
R6
088A-4
R6
106A-4
R8
145A-4
R8
169A-4
R8
206A-4
R8
U n = 480 V (IEC)
09A5-4
R3
12A7-4
R3
018A-4
R3
026A-4
R3
033A-4
R6
039A-4
R6
046A-4
R6
062A-4
R6
073A-4
R6
088A-4
R6
106A-4
R8
145A-4
R8
169A-4
R8
206A-4
R8
U n = 480 V (NEC)
07A6-4
R3
012A-4
R3
014A-4
R3
023A-4
R3
027A-4
R6
034A-4
R6
044A-4
R6
052A-4
R6
IEC 1)
Cu cable type
mm 2
3×2.5
3×2.5
3×6
3×10
3×10
3×16
3×25
3×35
3×50
3×70
3×95
3×120
3×150
3×2.5
3×2.5
3×2.5
3×6
3×10
3×10
3×16
3×25
3×35
3×50
3×70
3×95
3×120
3×150
3×2.5
3×2.5
3×2.5
3×6
3×10
3×10
3×16
3×25
Al cable type 2)
mm 2
-
-
-
3×16
3×16
3×25
3×35
3×50
3×70
3×70
3×120
3×150
3×240
-
-
-
-
3×16
3×16
3×25
3×35
3×50
3×70
3×70
3×120
3×150
3×240
-
-
-
-
3×16
3×16
3×25
3×35
UL (NEC) 3)
Cu cable type
AWG/kcmil
14
14
10
8
8
6
4
2
1/0
2/0
3/0
250 MCM
300 MCM
14
14
14
10
8
8
6
4
2
1/0
2/0
3/0
250 MCM
300 MCM
14
14
14
10
8
8
6
4

Advertisement