Installation - Thermo Scientific Shandon TissueWave 2 Operator's Manual

Microwave specimen processing system
Table of Contents

Advertisement

System
System
Specifi cation
Specifi cation
Locating the
Locating the
Shandon
Shandon
TissueWave 2
TissueWave 2
Power
Power
Requirements
Requirements
System Dimensions:
System Dimensions:
Microwave Chamber Dimensions:
Microwave Chamber Dimensions:
System Mass:
System Mass:
Input Current:
Input Current:
Microwave Output Power:
Microwave Output Power:
System Fusing:
System Fusing:
Temperature Readout Refresh Rate: Once per second
Temperature Readout Refresh Rate: Once per second
Temperature Readout Accuracy:
Temperature Readout Accuracy:
Power Control Accuracy:
Power Control Accuracy:
Air Agitation:
Air Agitation:
Vacuum Pump Capacity:
Vacuum Pump Capacity:
Internal Lighting:
Internal Lighting:
Fluid Ports:
Fluid Ports:
The Shandon TissueWave 2 should be located on a
level bench or tabletop
facility ventilation system
and a
Consideration should be given to the surrounding work space to
ensure that easy access to the material and equipment to be used
with the Shandon TissueWave is provided as well as an adequate
work surface area.
It is highly recommended that the Shandon TissueWave be connected
to a service outlet that is not used by any other device.
It should also be noted that the shortest possible distance between
the service outlet and mains connection feeding the service will
produce the best results in terms of consistent power output from the
Shandon TissueWave.

3 - Installation

19"H x 21.5"W x 24.5"D (48.2 x 54.6 x 62.2 cm)
19"H x 21.5"W x 24.5"D (48.2 x 54.6 x 62.2 cm)
9.5"H x 13.5"W x 15.5"D (24.1 x 34.3 x 39.4 cm)
9.5"H x 13.5"W x 15.5"D (24.1 x 34.3 x 39.4 cm)
78 lbs. (35.5 kg)
78 lbs. (35.5 kg)
14A at 120V Nominal / 7.3A at 230V Nominal
14A at 120V Nominal / 7.3A at 230V Nominal
825W Nominal (as measured by the 2 minute test method)
825W Nominal (as measured by the 2 minute test method)
2 x 15A Slow-Blow
2 x 15A Slow-Blow
Temperature Error < 0.5°C
Temperature Error < 0.5°C
Power Control Error < 1%
Power Control Error < 1%
Flow Rate = 61 in³/min (0.001 m³/min) Nominal
Flow Rate = 61 in³/min (0.001 m³/min) Nominal
Flow Rate = 2200 in³/min (0.036 m³/min)
Flow Rate = 2200 in³/min (0.036 m³/min)
40W Incandescent Light Bulb
40W Incandescent Light Bulb
Port size will accept up to 3/16" (5 mm) hose.
Port size will accept up to 3/16" (5 mm) hose.
with close proximity to
.
TissueWave 2 Operator Guide
non-flammable
electrical power
31