Series Specifications - CKD IO-Link FCM Series Manual

Io-link compatible compact flow rate controller
Table of Contents

Advertisement

Pressure
Standard differential pressure, working pressure differential *4, 5
(Standard model)
Standard differential pressure (kPa)
AI
Working pressure differential (kPa)
Max. working pressure (kPa)
Standard differential pressure (kPa)
AR
Working pressure differential (kPa)
Max. working pressure (kPa)
Standard differential pressure (kPa)
O2
Working pressure differential (kPa)
Max. working pressure (kPa)
Standard differential pressure (kPa)
LN/C1
Working pressure differential (kPa)
Max. working pressure (kPa)
Standard differential pressure (kPa)
C3
Working pressure differential (kPa)
Max. working pressure (kPa)
(Low differential pressure model)
Standard differential pressure (kPa)
AI/O2
LN/C1
Working pressure differential (kPa)
C3
Max. working pressure (kPa)
*8
Display, integrating functions
Display range
Flow rate
display
Display resolution
Display range
Integrating
Display resolution
functions *9
Pulse output rate
*1: The value converted to volumetric flow rate at standard condition (20 °C 1 barometric pressure (101 kPa) relative humidity 65%). Full scale stands for max.
scale flow rate in the flow rate range.
*2: Use dry gas which does not contain corrosive elements such as chlorine, sulfur or acids, and which is clean and does not contain dust or oil mist.
When using compressed air, use clean air compliant with JIS B8392-1: 2012 (ISO 8573-1: 2010) [1: 1: 1 to 1: 6: 2]. Compressed air from the compressor
contains drainage-water, oil oxide, foreign substances, etc. To maintain the function of this product, install a filter, air dryer (min. pressure dew point 10˚C or
less), and oil mist filter (max. oil concentration 0.1 mg/m
[Recommended circuit]
Filter
Pneumatic
Air dryer
source
[Recommended device]
Air filter: F Series
Oil mist filter: M Series
*3: The value for city gas 13A is a value for methane (CH
*4: Standard differential pressure is the differential pressure when this product is calibrated. (Secondary side released to atmosphere)
*5: Working pressure differential is the differential pressure required for normal operation of this product. Note that the values depend on the flow rate range and
applicable product(s) fluids. The min. value of the working pressure differential is the differential pressure required for the full scale flow rate to flow when secondary
side is released to atmosphere. The max. working pressure (max. value of working pressure differential) is the max. value of primary side pressure. If more
pressure is applied, control may become unstable, or the max. flow rate may not be controllable.
*6: Ensure that the current supply capacity per IO-Link master port is sufficient.
*7: This product's protection circuit is effective only for specific misconnections. It does not provide protection for all misconnections.
*8: The low pressure line (1 to 2.5kPa) of city gas is outside the working pressure differential range.
*9: The accumulated flow is a reference value. It is reset when the power is turned OFF
*10: The valve inside this product cannot be used as a stop valve requiring zero leakage. Slight leakage is allowed for in the specifications.
9500
0001
50
100
20 to 150
50 to 200
150
200
50
100
20 to 150
50 to 200
150
200
50
100
20 to 150
50 to 200
150
200
50
50
20 to 150
20 to 150
150
150
50
50
20 to 150
20 to 150
150
150
L9500
20
5 to 50
50
9500
0001
L9500
L0001
0 to 500 mL/min 0.00 to 1.00 L/min 0.00 to 2.00 L/min 0.00 to 5.00 L/min 0.0 to 10.0 L/min 0.0 to 20.0 L/min 0.0 to 50.0 L/min 0 to 100 L/min
1 mL/min
0.01 L/min 0.01 L/min 0.01 L/min
999999 mL 9999.99 L 9999.99 L 9999.99 L 99999.9 L 99999.9 L 99999.9 L
1 mL
0.01 L
5 mL
0.01 L
3
) on the primary side (upstream side) of this product.
Oil mist filter
(Micro alescer)
Regulator
FCM Series
) 88% gas generated from LNG.
4
Flow rate range *1
0002
0005
0010
100
100
100
50 to 250
50 to 250
50 to 250 100 to 300 150 to 300 250 to 350
250
250
250
100
100
100
50 to 250
50 to 250
50 to 250 100 to 300 150 to 300
250
250
250
100
100
100
50 to 250
50 to 250
50 to 250
250
250
250
50
50
50
20 to 150
20 to 150
30 to 150
150
150
150
50
50
50
20 to 150
20 to 150
30 to 150
150
150
150
Flow rate range *1
L0001
L0002
20
20
5 to 50
5 to 50
50
50
Flow rate range *1
0002
0005
0010
L0002
L0005
L0010
0.1 L/min
0.01 L
0.01 L
0.1 L
0.02 L
0.05 L
0.1 L
FCM
Series
Specifications
0020
0050
0100
150
200
300
300
300
350
150
200
300
300
L0005
L0010
20
20
5 to 50
10 to 50
50
50
0020
0050
0100
0.1 L/min
0.1 L/min
1 L/min
999999 L
0.1 L
0.1 L
1 L
0.2 L
0.5 L
1 L
2