The originating ISU 512e generates the 2047 patterns and checks the
incoming pattern for errors. The test is run for 120 seconds. The results
of the test are placed in the status buffer of the originating unit.
In addition, the ISU 512e can loop back a remote unit automatically at
the start of a BONDING call and run the 2047 pattern. This is accom-
plished through a smart dial string: <number> #5.
For example, the dial string 9224323#5 places a remote loopback call
to the remote unit. After BONDING connects, the originating unit dis-
plays the byte count and error count for the current test along with the
amount of time left in the test. The remote unit remains in protocol
loopback and displays the amount of time left before the unit(s) enter
data mode. This allows the originating side to complete the test and
write the results to the status buffer.
From the front panel, pressing
pressing
C
LEAR
Pressing
test causes the Originating unit to receive errors and
terminate the test. Pressing
unit before the end of the test does not terminate the test at
the Remote Site.
61203086L1-1
0
ends the test. From the terminal menu, the
Cancel
C
and S
T
OUNTS
TOP
EST
on the Remote unit before the end of the
Cancel
Cancel
ISU 512e User Manual
Chapter 5. Test Menu
clears the count and
activators are used.
on the Originating
5-3