Juniper EX9253 Hardware Manual page 185

Hide thumbs Also See for EX9253:
Table of Contents

Advertisement

Table 38: Chassis Component Alarm Conditions on EX9253 Switches
Chassis
Alarm Condition
Component
Feature usage requires a license
or the license for the feature
usage has expired.
Temperature
The temperature has exceeded
the defined threshold for the
fan
condition listed in the output
of
show chassis temperature-
thresholds
The temperature has exceeded
the defined threshold for the
Normal
output of
temperature-thresholds
command.
The temperature has exceeded
the defined threshold for the
alarm
condition listed in the
output of
temperature-thresholds
command.
Bad
command.
condition listed in the
show chassis
Red
show chassis
(Continued)
Alarm
Remedy
Severity
Minor
Install the required license for the feature
(yellow)
specified in the alarm. For more
information, see
Licenses for EX Series
Minor
Check room temperature.
(yellow)
Check air filter and replace it, if
required.
Check airflow.
Replace the fan tray.
Minor
Check room temperature.
(yellow)
Check air filter and replace it, if
required.
Check airflow.
Check the fans.
Major (red)
Check room temperature.
Check air filter and replace it, if
required.
Check airflow.
Check the fans.
Understanding Software
Switches.
176

Advertisement

Table of Contents
loading

Table of Contents