• Issue the show chassis fpc command to check the status of installed line cards. As shown in the sample
output, the value Online in the column labeled Slot State indicates that the line card is functioning
normally:
user@switch> show chassis fpc
(%)
Slot State
Heap
Buffer
0 Online
1 Empty
NOTE: The show chassis fpc command displays the status of the line cards.
For more detailed output, add the detail option. The following example does not specify a slot
number, which is optional:
user@switch> show chassis fpc detail
Slot 0 information:
State
Total CPU DRAM
Total RLDRAM
Total DDR DRAM
Temperature
Start time
Uptime
Max MPC base power consumption
Max MIC1 power consumption
Max MPC total power consumption 1065 Watts
Temp CPU Utilization (%)
(C) Total Interrupt
52
17
0
Online
3136 MB
771 MB
18432 MB
52 degrees C / 125 degrees F
2018-06-14 00:37:49 UTC
30 minutes, 35 seconds
910 Watts
155 Watts
CPU Utilization (%) Memory
1min
5min
15min DRAM (MB)
20
22
23
3136
164
Utilization
12
11