6.2 PROGRAMMING

+
/R1
When the display shows the automation status, you
can enter basic or advanced programming mode.
1 2 3 4 5 6 7 8
9 10 11
M1
M2
LAMP
■ Basic programming
1. Press and hold the
The first function (
which is displayed as long as button F remains
C
C
pressed.
M
M
2. Release the button: the display shows the value
230
V~
60 W max
of the function.
+ +
3. Press the
F F
button to confirm to go to the next function.
Proceed in the same way for all the functions.
■ Advanced programming
1. Press and hold down the
button as well:
The first function (
which is displayed as long as button F remains
pressed.
2. Release the buttons: the display shows the value
of the function.
+ +
3. Press the
F F
button to confirm to go to the next function.
Proceed in the same way for all the functions.
■ Exiting programming mode
i
Every modified value becomes effective immediately,
but when exiting from programming mode you have
to decide whether to save the modifications or not.
Modifications are lost if no buttons have been pressed
for 10 minutes or if power to the board is disconnected
before they have been saved.
1. Press and hold down the
button as well.
Alternatively, scroll through the programming
menu until you reach the last function (
2. Select:
Y
= save the changes
no
= DO NOT save the changes
3. Press button
the automation status view.
E045S
-
F
/R2
15 16 17 18
20 21
F F
button:
dF
) appears on the display,
"
24 V
3 W max
or - - button to modify, then press the
F F
button, then the
bo
) appears on the display,
or - - button to modify, then press the
F F
button, then the + +
F F
to confirm: the display reverts to
2EASY
 2 BASIC programming menu
Function
dF
DEFAULT CONFIGURATION
Displays
default settings. Select
the default values.
Y
USB-A
DEFAULT settings
no
the default settings
Lo
FUNCTIONING LOGIC
E
EP
SP
A
AP
b
C
PA
PAUSE TIME
+ +
(displayed only if an automatic logic has been
selected)
Displayed in seconds up to 59, then in steps of 10 s.
00
1.0
Mn
NUMBER of MOTORS connected
1
2
F1
MOTOR 1 POWER
01
F2
MOTOR 2 POWER
(displayed only if
01
En
ENCODER
Enables/disables the encoder on both motors.
no
Y
Cd
LEAF CLOSING DELAY
(displayed only if
St
).
The delay is applied to MOTOR 1.
Displayed in seconds up to 59, then in steps of 10 s.
00
1.0
bu
Learn BUS 2easy devices
See the relative section.
M2
MOTOR 2 OPERATION in dead man mode
(displayed only if
+
-
12
Y
if the programming corresponds to the
Y
if you wish to reload
the programming corresponds to the
the programming DOES NOT correspond to
Semi-automatic
Semi-automatic step by step
Automatic Safety Step by Step
Automatic
Automatic Step by Step
Semi-automatic b
Hold-to-run
59
...
(Adjustment step: 1 s)
9.5
...
(Adjustment step: 10 s)
1 motor
2 motors
50
50
...
(levels;
=maximum power)
Mn
2
)
=
50
50
...
(levels;
=maximum power)
disabled
enabled
Mn
2
=
)
59
...
(Adjustment step: 1 s)
1.3
...
(Adjustment step: 10 s)
Mn
2
=
)
oP
OPEN (displaying
)
cL
CLOSE (displaying
)
532373 - Rev.A
default
Y
E
30
2
25
25
no
05
no
--