Specification - Smartgen HFC6100LT User Manual

Fan controller
Table of Contents

Advertisement

3 SPECIFICATION

Items
Working Voltage
Power Consumption
AUX. Output 1~12
PWM 1-4
Digital Input 1-16
Digital Input 17-18
RS485
Vibration
Shock
Bump Test
Production Compliance
Overall Dimensions
Panel Cutout
Working Condition
Storage Condition
Protection Level
Weight
HFC6100LT Fan Controller User Manual
Table 2 – Performance Parameters
Continuous power supply: DC8.0V to DC35.0V
<4W(Standby mode: ≤2W)
1A
DC24V
Transistor B+ output
1A
DC24V
Transistor B+ output
Frequency
100Hz
Duty Ratio
0~100%
Low threshold voltage is 2.8V; high limit voltage is 60V
Low threshold voltage is 1.2V; high limit voltage is 60V
Isolated, half-duplex, 9600 baud rate,
maximum communication length 1000m
5 - 8 Hz: ±7.5 mm
8 - 500 Hz: 2 g
IEC 60068-2-6
50g, 11ms, half-sine, complete shock test from three directions, and
18 times shock for each test
IEC 60068-2-27
25g, 16ms, half-sine
IEC 60255-21-2
According to EN 61010-1 installation category (over voltage
category) III, 300V, pollution class 2, altitude 3000m
209mm x 167mm x 45mm
186mm x 141mm
Temperature: (-40~+70)ºC
Temperature: (-40~+80)ºC
Front panel: IP65, when waterproof gasket ring inserted between
panel and housing.
Rear panel:IP20
0.6kg
Contents
Relative Humidity: (20~93)%RH
Page 5 of 24