4 SPECIFICATION

Parameter
Working Voltage
Overall Consumption
Voltage Input:
3 Phase 4 Wire
3 Phase 3 Wire
Single Phase 2 Wire
2 Phase 3 Wire
DC
Alternator Frequency
Speed Sensor Voltage
Speed Sensor Frequency
Start Relay Output
Fuel Relay Output
Configurable Relay Output 1 8A DC28V power supply output
Configurable Relay Output 2 8A DC28V power supply output
Configurable Relay Output 3 8A DC28V power supply output
Configurable Relay Output 4 8A AC250V free volt output
Light Control Relay Output
1~4
Light Control Relay Output
5~8
Case Dimensions
Panel Cutout
CT Secondary Current
DC Current Input
Working Conditions
Storage Conditions
Protection Level
Insulation Intensity
Weight
ALC700 Series Light Tower Set Controller
Details
DC8. 0V to 35. 0V, uninterruptible power supply
<5W (Standby mode: ≤2W)
AC 20V - 360V (ph-N)
AC 30V - 600V (ph-ph)
AC 20V - 360V (ph-N)
AC 20V - 360V (ph-N)
DC 0V - 75V (ph-N)
50Hz/60Hz
1. 0 V to 24 V (RMS)
Maximum 10,000 Hz
8A DC28V power supply output
8A DC28V power supply output
8A AC250V free volt output (total output current: 8A)
If 1~4 is all used, the maximum current of each light is 2A.
8A AC250V free volt output (total output current: 8A)
If 1~4 is all used, the maximum current of each light is 2A.
197 mm x 152 mm x 47 mm
186mm x 141mm
Rated: 5A
Hall sensor's secondary side current: (4~20)mA
Temperature: (-25~+70)°C
Relative Humidity: (20~93)%RH
Temperature:(-25~+70)°C
IP55. If water-proof gasket is inserted between panel and
enclosure.
Apply AC2.2kV voltage between high voltage terminal and
low voltage terminal;
The leakage current is not more than 3mA within 1min.
0.71kg
2018-03-02
ALC700 Series Light Tower Set Controller
Version 1.4
Page 9 of 51