1
System Description
DC mode (optional)
DC Output Rating
Current rise time (10% to 90%)
Voltage dynamic (10% to 90%)
Load regulation
Harmonic
Harmonic Synthesis
Progr. Harmonics and interharmonics
Harmonics voltage injection
Individual voltage harmonic amplitude output
accuracy, n=2-50
Individual voltage harmonic phase angle output
accuracy, n=2-50
Harmonics current injection
Individual current harmonic amplitude output
accuracy, n=2-50
Individual current harmonic phase angle output
accuracy, n=2-50
Harmonic Measurements
Voltage/Current THD Measurement
Individual Voltage Harmonic Amplitude
Measurement, accuracy n = 2 to 50
Individual Voltage Harmonic Phase Angle
Measurement, accuracy n = 2 bis 50
Individual Current Harmonic Amplitude
Measurement, accuracy n = 2 to 50
Individual Current Harmonic Phase Angle
Measurement, accuracy n = 2 bis 50
Frequency measurement bandwidth
10
Measurement of Harmonic Phase Angle when in Current Priority mode requires current flow; 1 A minimum load
per phase is recommended.
24/51
<2 ms
500 V/ms
0.25% FS
✓
up to 50
th
±0.5% ±0.25 V
0. 1˚ x n±1˚
up to 50
th
±0.5% ±0.5 A
0. 1˚ x n±1˚
up to 50
th
±0.5% ±0.25 V
0. 1˚ x n±1˚
±0.5% ±0.5 A
0. 1˚ x n±1˚
20 kHz
Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions
10