1
System Description
Intended Use
NOTICE
Foreseeable Misuse
Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions
The SL1200A Series Scienlab Regenerative AC Emulator is used for testing
the power electronics of charging systems and other components that can be
operated on any power grid, in particular
1-, 2- or 3-phase emulation of AC sources (Voltage Priority) up to a
voltage line-to-line 600 V
grid),
1-, 2- or 3-phase emulation of AC sink (Current Priority),
1-, 2- or 3-phase emulation of harmonics with order 0 to 50, as well as two
interharmonics with freely specified frequency fx of up to 3750 Hz,
optional: emulation of a DC source/sink (Voltage/Current Priority) up to
500 V or 1000 V.
The SL1200A can be integrated in a comprehensive test solution for
photovoltaic inverters (PV), battery energy storage inverters, and other
types of grid-connected inverters,
energy storage systems, in conjunction with the Scienlab Charging
Discovery System (PHEV, EVSE, OBC).
The Scienlab Regenerative AC Emulator may only
be operated in within the current, voltage and power ranges indicated in
the Section
Technical
The system is built according to the applicable directives, the latest state of
the art, and recognized safety regulations.
The system must only be used in accordance with its intended uses. This is a basic
requirement for trouble-free and reliable operation. The system must be in safe
condition before it is commissioned.
The following in particular shall be deemed to be improper use:
Any other use than that laid down in
the operating instructions without the written consent of the manufacturer,
Use, installation, operation, maintenance or repair of kind or manner other
than described and by unqualified personnel,
Use of non-approved, inappropriate accessories,
Non-compliance with safety and operating instructions, occupational
safety and accident prevention regulations or relevant statutory
regulations,
Failure to eliminate faults that may impair safety in a timely manner,
(low-voltage grid), or 1200 V
rms
Data.
Intended Use
System Description
(high-voltage
rms
and further described in
15/51
1