Keysight SL1200A Series Operating Instructions Manual

Keysight SL1200A Series Operating Instructions Manual

Scienlab regenerative ac emulator
Hide thumbs Also See for SL1200A Series:
Table of Contents

Advertisement

Quick Links

SL1200A Series
Scienlab Regenerative AC Emulator
Low Voltage & High Voltage
OPERATING INSTRUCTIONS

Advertisement

Table of Contents
loading

Summary of Contents for Keysight SL1200A Series

  • Page 1 SL1200A Series Scienlab Regenerative AC Emulator Low Voltage & High Voltage OPERATING INSTRUCTIONS...
  • Page 2: Table Of Contents

    Additional DC mode connection (optional) .............. 32 Connecting load lines ..................32 Connecting sense lines ..................32 Using an emulator adapter with a Scienlab Charging Discovery System ....32 2/51 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions...
  • Page 3 General Instructions for Upkeep ................... 47 Carrying out Inspection Work ................... 48 Cleaning the system ....................49 Decommissioning ......................50 Temporary Decommissioning ..................50 Storage Conditions ......................50 Dismantling, Final Decommissioning ................50 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions 3/51...
  • Page 4: Notices

    U.S. government may use, modify, distribute, or disclose the Software. The EULA and the license set forth therein, does not require or permit, among other things, that Keysight: (1) Furnish technical information related to commercial computer software or commercial computer software documentation that is not customarily provided to the public;...
  • Page 5 FAR and the DFARS and are set forth specifically in writing elsewhere in the EULA. Keysight shall be under no obligation to update, revise or otherwise modify the Software. With respect to any technical data as defined by FAR 2.101, pursuant to FAR 12.211 and 27.404.2 and DFARS 227.7102, the U.S.
  • Page 6 Do not proceed beyond a NOTICE until the indicated conditions are fully understood and met. NOTE A NOTE refers exclusively to application notes without any security relevance. 6/51 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions...
  • Page 7: Safety And Regulatory Notices

    Keysight Technologies assume no liability for the customer´s failure to comply with these requirements. Please read the also the section Intended Use.
  • Page 8 • On the front side • Press: forces local emergency stop of the system (Responds: see safety relay) • Turn counterclockwise: unlocks • Functional test of the emergency stop button: monthly 8/51 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions...
  • Page 9 • Reaction: Feedback signal is detected → undervoltage monitoring reacts → the main switch cannot be activated (falls back to position Trip) • Consequence: Surge protection inlets must be changed by KeysightCare, feedback contact is reset Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions 9/51...
  • Page 10 (red light). All other systems switch to the ready status (green light). All other systems switch to the standby/ready status (green light). 10/51 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions...
  • Page 11 The China RoHS mark indicates that toxic substance within the product stay inside at least 40 years before expiring. ccr.keysight@keysight.com Contact address for questions to conformity of the product. Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions 11/51...
  • Page 12: User Information

    These Operating Instructions is part of the SL1200A Series Scienlab Regenerative AC Emulator and should always be kept at the system´s place of use.
  • Page 13 Keysight recommend first connecting the system to the higher-level safety and emergency stop system of the test bench, before putting it into operation. The Keysight emergency stop system in the control cabinet may not be changed or adapted without the consent of Keysight.
  • Page 14 User Information Contact KeysightCare – Technical Support Contact KeysightCare Keysight Technologies Technical Support www.keysight.com/find/keysightcare-contact 14/51 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions...
  • Page 15: System Description

    System Description System Description Intended Use The SL1200A Series Scienlab Regenerative AC Emulator is used for testing the power electronics of charging systems and other components that can be operated on any power grid, in particular 1-, 2- or 3-phase emulation of AC sources (Voltage Priority) up to a...
  • Page 16: Functional Description

    Voltage Priority with different output voltages. If, for example, a charging TN/TT grid: The generated phases have a potential reference to grounding (PE). IT grid: The generated phases are electrically isolated from grounding (PE). 16/51 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions...
  • Page 17 Optionally, the system is equipped with an extended safety device (Increased Safety function, - ST2/SD2 option). Before the system can be switched on via the main switch, the safety relay checks all safety-relevant switching Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions 17/51...
  • Page 18: System Arrangement

    STD – Standard Cabinet SDC – Standard Cabinet with DC power source ST2 – Standard Cabinet with Increased Safety SD2 – Standard Cabinet with DC power source and Increased Safety 18/51 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions...
  • Page 19 System Description Figure 2: System arrangement Scienlab Regenerative AC Emulator (left front side, right rear side) (illustration similar) Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions 19/51...
  • Page 20: Technical Data

    <85 dB(A) at a distance of 1 m from the front Maximum operating altitude 2.000 m AMSL Communication interface To control PC, for parallel connection of various Scienlab Ethernet LAN Regenerative AC Emulators 20/51 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions...
  • Page 21: Electrical Specification

    Specification valid in single-phase mode for an output voltage of 15 … 346 V / 26 … 600 V (SL1201A – SL1203), 15 … 692 V / 26 … 1200 V (SL1212A, SL1213A) Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions 21/51...
  • Page 22: Dc Mode (Optional)

    0.1 V ±0.03% ±0.03% ±0.03% ±0.03% accuracy ±0.03% ±9 mA Current ±18 mA ±18 mA ±36 mA ±18 mA measurement resolution 0.1 A Specification valid in single-phase mode 22/51 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions...
  • Page 23: Supplemental Characteristics

    Irms=30A) (SL1213A) Full voltage dropouts at faster speeds (approx. 50 µs) can be achieved using Phase Loss/Dropout (see Getting Started Guide). Transition speed to any voltage to 0 V Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions 23/51...
  • Page 24: Dc Mode (Optional)

    Measurement, accuracy n = 2 bis 50 Frequency measurement bandwidth 20 kHz Measurement of Harmonic Phase Angle when in Current Priority mode requires current flow; 1 A minimum load per phase is recommended. 24/51 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions...
  • Page 25: Transport And Installation

    Transport and installation work on the system may only be carried out by specially NOTICE trained personnel. (see Qualification of the Personnel) Figure 3: SL1200A with 45 kVA (left) and 90 kVA configuration (exemplary) Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions 25/51...
  • Page 26: Means Of Transportation

    Do not use tools with sharp-edges to open the packing. The system can be damaged if the packaging is opened improperly. The protective film must be removed to unpack the system. 26/51 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions...
  • Page 27: Installing The System

    Disposing of the packaging material A recyclable plastic film is used as the packaging material. The plastic film is made of polyethylene. Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions 27/51...
  • Page 28: Connection And Assembly

    Cover or block off neighboring live parts. Assembly, connection and electrical work on the system may only be carried out by NOTICE specialist staff and specially trained personnel. (see Qualification of the Operating Personnel) 28/51 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions...
  • Page 29: Electrical Installation

    Data. To ensure that EMC limit values are adhered to, it is important that the shielding of NOTE the EMC cable feedthrough fully surrounds the shielding of the cable. Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions 29/51...
  • Page 30: Housing Ground/Functional Earth

    SL1200A to reduce and systematically dissipate electromagnetic/electrical interference. Housing ground/functional earth • On the rear side of the system • Connection and coupling of housing ground • Connection for EMC-compliant design 30/51 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions...
  • Page 31: Connection Of Dut (Device Under Test) (Output)

    Connection of sense lines, AC HV + LV • Connect to the fuses according to circuit diagram • Measure DUT voltage U sense • From left to right: L1, L2, L3, N • Wire end ferrules Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions 31/51...
  • Page 32: Additional Dc Mode Connection (Optional)

    Scienlab Regenerative AC Emulator, which is permanently installed with the output box and no connection inside the outbox is needed. 32/51 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions...
  • Page 33: Connecting An Emulator Adapter

    Replace the bottom flange plate with the corresponding bottom flange plate for the emulator adapter. Replace the connections as described follows. Emulator adapter • Example: DC emulator adapter • DC+, DC-, PE, Pilot1 + 2, LV_PL3 + 4 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions 33/51...
  • Page 34: Parallel Connection

    • Ethernet connection ports (use RJ45 connectors) • For parallel connection director/follower systems (see Figure The following Figure 5 shows an example for a parallel connection via Remote Power Terminal (RPT). 34/51 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions...
  • Page 35: Connecting Signal And Control Lines

    For connection, use the RJ45 connectors included in the scope of delivery. Furthermore, there are interfaces (BNC sockets) for trigger input and trigger output signals. For connection the RJ45 connectors, please refer to the supplied assembly NOTE instructions. Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions 35/51...
  • Page 36: Connecting Higher-Level Safety Technology

    Keysight recommend first connecting the system to the higher-level safety and emergency stop system of the test bench, before putting it into operation. The Keysight emergency stop system in the control cabinet may not be changed or adapted without the consent of Keysight.
  • Page 37 23 - 24: feedback AC contactors 25 – 26: feedback DC contactors Table 4: Pin assignment Release and Emergency stop In/Out The figure below shows the overview of the emergency/safety contact: Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions 37/51...
  • Page 38: Connecting Signal Lamp

    Socket for connecting signal lamp • Connection socket on the roof of the system • System checks correct connection of the signal lamp after switching on 38/51 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions...
  • Page 39: Commissioning

    PC software and firmware, available via Keysight Homepage (Software/Firmware), are installed. Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions 39/51...
  • Page 40: Procedure For Switching On/Off

    The SL1200A is in standby/ready mode, the power path is inactive, the ✓ logic path is still active. Turn the circuit breaker switch to 0 (OFF). The SL1200A is completely switched off. ✓ 40/51 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions...
  • Page 41: Initial Commissioning

    • ON: test release given, test may be started (e.g. acknowledged by software) 4 External release function is released, if applicable (pre-equipped or if the external release function is not used a jumper/bridge must be established) Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions 41/51...
  • Page 42: Recommissioning

    Provided the ambient conditions are right, the SL1200A is operational ✓ after a start-up period of 2 minutes. Recommissioning After prolonged storage, the same steps as performed for initial commissioning are required, see Section Performing Initial Commissioning. 42/51 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions...
  • Page 43: Action In An Emergency

    • O OFF: Circuit breaker has triggered → system is inactive; all power and communication connections (logic path) are inactive. • I ON: Logic path active, system can be activated via main switch Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions 43/51...
  • Page 44: Switching Off In An Emergency

    If the main switch is set to “Trip” due to activation of the emergency stop (undervoltage triggering) Before switching the system on again, set the main switch to “OFF”. Only then set the main switch to “ON” to switch back on. 44/51 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions...
  • Page 45: Troubleshooting And Fault Elimination

    Not properly wired external emergency/release Check wiring inside the SL1200A in/out Connectivity problem Check cabling When option Increased Safety is available: Contact KeysightCare connectors defect Table 5: Possible cause and remedy Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions 45/51...
  • Page 46: Test Cannot Be Started

    (falls back to position Trip • Consequence: Surge protection inlets must be changed by KeysightCare, feedback contact is reset Inserts may only be replaced by local NOTE KeysightCare staff. 46/51 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions...
  • Page 47: Upkeep And Inspection

    In case of connected DUT, the output terminals can still carry voltages even after switch-off of the system! Measure the voltage at the outputs to ensure that they are voltage-free. cf. DIN EN 13306, IEC 60050 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions 47/51...
  • Page 48: Carrying Out Inspection Work

    Option Increased Safety: Functional check of monthly recommended circuit breaker Visual inspection of signal lamp annually Check noise generation of the fan of power stages Table 9: Inspection works when switched on 48/51 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions...
  • Page 49: Cleaning The System

    3 Measure the voltage at the output and terminals to ensure that they are de-energized, 4 Wipe the housing, display modules and front panels with a dry, clean and lint-free cleaning cloth. Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions 49/51...
  • Page 50: Decommissioning

    3 Disconnect all further lines (signal and control lines, load and measuring lines) and roll up the cables. Disassemble and decommission the system by performing the steps in reverse order. All system parts must be disposed of professionally. 50/51 Scienlab Regenerative AC Emulator – SL1200A Series – Operating Instructions...
  • Page 51 This information is subject to change without notice. © Keysight Technologies 2020 - 2022 Edition 1.4, September 2022 www.keysight.com...

This manual is also suitable for:

Sl1201aSl1202aSl1203aSl1212aSl1213a