4 Mounting
Mount into the vessel
Mounting into the basin
14
4.4
Mounting steps with threaded connection or
housing
Fig. 8: Plastic housing
1
Housing
2
Seal
3
Thread
Mount VEGAWELL 52 as follows:
1. Weld the welded socket G1½ or 1½ NPT to the vessel top
2. Shift transmitter through the mounting boss
3. Turn the thread with seal into the nozzle and tighten with SW 46
Disassembly is carried out in reverse order.
Mount VEGAWELL 52 as follows:
1. Fasten the mounting bracket at the suitable height on the basin
wall
2. Lead the transmitter through the opening of the mounting bracket
and the counter nut
3. Fasten counter nut with SW 46 on the thread
Seal with resistant material with thread 1½ NPT.
1)
1
2
3
VEGAWELL 52 • 4 ... 20 mA/HART Pt 100
1)