8 Maintenance and fault rectification

Maintenance

Cleaning
Reaction when malfunc-
tion occurs
Causes of malfunction
Fault rectification
24 hour service hotline
Check the 4 ... 20 mA
signal
26
8 Maintenance and fault rectification
8.1
Maintenance
If the device is used properly, no special maintenance is required in
normal operation.
In some applications, product buildup on the diaphragm can influence
the measuring result. Depending on the sensor and application, take
precautions to ensure that heavy buildup, and especially a hardening
thereof, is avoided.
If necessary, clean the diaphragm. Make sure that the materials are
resistant against the cleanig, see resistance list under " Service" on "
www.vega.com".
8.2

Rectify faults

The operator of the system is responsible for taking suitable meas-
ures to rectify faults.
The device offers maximum reliability. Nevertheless, faults can occur
during operation. These may be caused by the following, e.g.:
Sensor
Process
Voltage supply
Signal processing
The first measures to be taken are to check the output signals as well
as to evaluate the error messages via the display and adjustment
module. The procedure is described below. Further comprehensive
diagnostics can be carried out on a PC with the software PACTware
and the suitable DTM. In many cases, the causes can be determined
and the faults rectified this way.
Should these measures not be successful, please call in urgent cases
the VEGA service hotline under the phone no. +49 1805 858550.
The hotline is manned 7 days a week round-the-clock. Since we offer
this service worldwide, the support is only available in the English
language. The service is free, only standard call charges are incurred.
Connect a multimeter in the suitable measuring range according to
the wiring plan.
Error code
Cause
4 ... 20 mA sig-
Level fluctua-
nal not stable
tions
No atmospheric
pressure com-
pensation
Rectification
Set damping
Check the capillariy and cut it clean
Check the pressure compensation in
the housing and clean the filter element,
if necessary
VEGAWELL 52 • 4 ... 20 mA/HART Pt 100