7   Operation
7   OPERATION
7.1   TRAINING THE OPERATING PERSONNEL
– The operating personnel must be qualified to operate the entire system.
– The operating staff must be familiar with the potential risks associated with improper
behavior as well as the necessary protective devices and measures.
– Before work commences, the operating personnel must receive appropriate system
training.
7.2   EMERGENCY STOP
In the case of unforeseen occurrences immediately:
1. Close the air cut-off valve (4) or the pressure regulator (3) immediately. The cut-off valve
(4) is not supplied with the pump. It must be provided and properly installed by the
user.
2. Open the return valve (2, if installed) and/or the delivery devices (valves or guns).
1
2
3
4
5
6
A
8
B_06954
B
A
closed
7.3   TASKS
Ensure that:
commissioning is carried out in accordance with Chapter Commissioning [8 35].
1. Carry out a visual inspection: Personal protective equipment, grounding and all devices
ready for use.
2. Secure spray gun and insert nozzle into the spray gun.
3. Slowly open the shut-off valve (4).
4. The pump supplies the product (9) while the product delivery valve (1) is open. Change
the air pressure with the air pressure regulator (3), in order to achieve the desired
amount or product pressure.
5. Start work process.
Order number DOC 2330426 | Edition 09/2021
7
9
B
open
37