Operating manual Pneumatic double diaphragm pump ZIP52 - ZIP80
4 Basic Safety Instructions
4 Use only WAGNER original spare parts and accessories.
4 Do not change or modify the device; if change is necessary, contact WAGNER.
4 Only repair and replace parts that are listed in Chapters Accessories and Spare Parts
[8 56] and that are assigned to the device.
4 Do not use any defective components.
4 Before all work on the device and in the event of work interruptions:
4 Relieve the pressure from the spray gun, product hoses and all devices.
4 Secure the spray gun against actuation.
4 Switch off the energy and compressed air supply.
4 Disconnect the control unit from the mains.
4 Observe the operating and service manual for all work.
4.2.8 Protective and Monitoring Equipment
Danger due to removal of protective and monitoring equipment!
Danger to life and equipment damage.
4 Protective and monitoring equipment must not be removed, modified or rendered
unusable.
4 Regularly check for perfect functioning.
4 If defects are detected on protective and monitoring equipment, the system must not
be operated until these defects are remedied.
Order number DOC 2330426 | Edition 09/2021
19