WAGNER ZIP52 Translation Of The Original Operating Manual page 30

Pneumatic double diaphragm pump
Table of Contents

Advertisement

Operating manual Pneumatic double diaphragm pump ZIP52 - ZIP80
6   Assembly and Commissioning
Info
Ensure that the national explosion prevention rules and regulations are observed when
setting up the device.
Connections Configurations
B_07862
Type 1
(Feeding of a medium)
Connections specified
For pump type 2, the connections on the suction and delivery manifolds can be freely
selected. The pump is delivered with a standard connection configuration (side
connections). In this case, the connections marked with an asterisk (*) are closed with sealing
plugs.
If a connection configuration which deviates from the standard is selected, the glued in
sealing plugs must be unscrewed and changed accordingly.
If there is adhesive residue on the thread of the plug and the drilled hole, after the plugs
have been unscrewed, this residue must be removed with a wire brush. Then, the thread is
to be cleaned with a clean cloth.
Depending on the pump, the sealing plugs must either be glued in or wrapped in PTFE tape
when screwing them in!
Information on the glue, PTFE tape and the sealing plug can be found in chapter Spare Parts
[8 56].
30
*
*
*
B_07863
*
Type 2
(Feeding of a medium)
Connections can be selected
B_04021
Type 3
(Feeding of two mediums)
Connections specified
Order number DOC 2330426 | Edition 09/2021