6   Assembly and Commissioning
B_04011
Compressed air connection:
The compressed air supply must be properly dimensioned. Connect the pump's compressed
air connection to the pressure distribution network. Establish the connection to the pump
fitting. Do not replace the original connection. Use a line with a suitable diameter for the
connection. Always mount an air cut-off valve and an air processing unit (filter/regulator
unit). The pressure must not exceed the maximum value indicated on the type plate.
Non-return valve:
If the pump has been installed on a higher level than the liquid to be pumped, it is
recommended that a non-return valve be provided at the lower end of the suction tube.
6.5.1   Ventilation of the Spray Booth
– Operate the device in a spray booth approved for the respective working materials.
- or -
– Operate the device on an appropriate spraying wall with the ventilation (extraction)
switched on.
– Observe national and local regulations for the exhaust air speed.
6.5.2   Air Supply Lines
WARNING
Hose connections!
Risk of injury and damage to the device.
4 Do not mix up hose connections of product hose and air hose.
4 Ensure that only dry, clean atomizing air is used in the spray gun! Dirt and moisture in
the atomizing air worsens the spraying quality and spray pattern.
32
×
Order number DOC 2330426 | Edition 09/2021