WAGNER ZIP52 Translation Of The Original Operating Manual page 23

Pneumatic double diaphragm pump
Table of Contents

Advertisement

Operating manual Pneumatic double diaphragm pump ZIP52 - ZIP80
5   Description
Pump body
Description
Product temperature
Ambient temperature
Allowable inclination for operation
1. PF = Perfect Flow = low pulsation pump with a shorter stroke
2. Pump with stainless steel valves (start condition: empty pump / dry valves)
3. Pump with plastic valves (start condition: empty pump / dry valves)
4. LqA (10s)
5. ISO 3744
WARNING
Exhaust air containing oil!
Risk of poisoning if inhaled.
4 Provide compressed air free from oil and water.
5.5.3   Technical Data for Non-metallic Pumps
Pump body
Description
Pump ratio
Volume flow per double stroke
Maximum operating pressure
Maximum speed
Maximum flow rate
Compressed air quality: free from oil and water
Minimum air inlet pressure
Maximum air inlet pressure
Order number DOC 2330426 | Edition 09/2021
Al
Units
Zip 52
--
°C
°F
--
°C
°F
∠°
--
PP
Units
Zip 52
--
--
--
cm³
108
cu inch
6.59
--
MPa
bar
psi
--
DH/min
(1)
l/min
52
GPM
13.7
--
Quality standard 7.5.4 according to ISO 8573.1: 2010
--
--
7: Particle concentration 5–10 mg/m³
5: Humidity: Pressure dew point: ≤ +7 °C
4: Oil content: ≤ 5 mg/m³
--
MPa
0.15
bar
1.5
psi
22
--
MPa
bar
psi
SSt
Al
Zip 52
ZIP 52 PF Zip 80
4 – 90
39 – 194
4 – 40
39 – 104
± 10°
PP
Acetal
Acetal
ZIP 52 PF
Zip 52
ZIP 52
1 : 1
62
108
3.78
6.59
0.8
8
116
490
28
52
7.4
13.7
0.10
0.15
1.0
1.5
15
22
0.8
8
116
Al
PF
62
3.78
28
7.4
0.10
1.0
15
23